Ignore:
Timestamp:
Mar 5, 2026, 4:37:59 PM (7 days ago)
Author:
asima
Message:

Concerning "year_fr" :

  • (related to r6087) : use “float” for “integer” variables “year_cur” and “days_elapsed” ;
  • extend the range of available year_weight values to 2023, as in SPv2.1_1850-2023_CMIP7.nc
File:
1 edited

Legend:

Unmodified
Added
Removed
  • LMDZ6/trunk/libf/phylmd/macv2sp.f90

    r6087 r6091  
    8080  !--fractional year
    8181  !
    82   ! Adriana Sima et FH : Version bugguée :
     82  ! Original version, bugged :
    8383  ! year_fr = FLOAT(year_cur) + (FLOAT(day_cur)-0.5) / FLOAT(year_len)
    84   year_fr=year_cur+days_elapsed/float(year_len)
     84  ! Correction ASima & FH :
     85  year_fr= float(year_cur) + float(days_elapsed)/float(year_len)
    8586
    86   IF (year_fr.LT.1850.0.OR.year_fr.GE.2021.0) THEN
     87  IF (year_fr.LT.1850.0.OR.year_fr.GE.2024.0) THEN
    8788     CALL abort_physic ('macv2sp','year not supported by plume model',1)
    8889  ENDIF
Note: See TracChangeset for help on using the changeset viewer.