Changeset 3411 for LMDZ6/branches/DYNAMICO-conv/DefLists/field_def_lmdz.xml
- Timestamp:
- Nov 5, 2018, 3:24:59 PM (6 years ago)
- Location:
- LMDZ6/branches/DYNAMICO-conv
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
LMDZ6/branches/DYNAMICO-conv
- Property svn:mergeinfo changed
/LMDZ6/trunk removed
- Property svn:mergeinfo changed
-
LMDZ6/branches/DYNAMICO-conv/DefLists/field_def_lmdz.xml
r3356 r3411 7 7 <!-- </field_group> --> 8 8 9 <field_group id="coordinates" grid_ref="grid_glo">10 <field id="io_lon" />11 <field id="io_lat" />12 </field_group>13 14 9 <field_group id="coord_hyb"> 15 10 <field id="Ahyb" axis_ref="klev" /> … … 24 19 <field id="contfracATM" long_name="% sfce ter+lic" unit="-" /> 25 20 <field id="contfracOR" long_name="% sfce terre OR" unit="-" /> 26 <field id="sza" long_name="Solar zenithal angle " unit="deg" />27 21 <field id="flat" long_name="Latent heat flux" unit="W/m2" /> 28 22 <field id="slp" long_name="Sea Level Pressure" unit="Pa" /> … … 31 25 <field id="tsol" long_name="Surface Temperature" unit="K" /> 32 26 <field id="t2m" long_name="Temperature 2m" unit="K" /> 33 <field id="tasmax" field_ref="t2m" operation="maximum" />34 <field id="tasmin" field_ref="t2m" operation="minimum" />35 27 <field id="t2m_min" long_name="Temp 2m min" unit="K" operation="minimum" /> 36 28 <field id="t2m_max" long_name="Temp 2m max" unit="K" operation="maximum" /> … … 44 36 <field id="wind10m" long_name="10-m wind speed" unit="m/s" /> 45 37 <field id="wind10max" long_name="10m wind speed max" unit="m/s" /> 46 <field id="sfcWindmax" field_ref="wind10m" operation="maximum" />47 38 <field id="sicf" long_name="Sea-ice fraction" unit="-" /> 48 39 <field id="q2m" long_name="Specific humidity 2m" unit="kg/kg" /> … … 78 69 <field id="ndayrain" long_name="Number of dayrain(liq+sol)" unit="-" /> 79 70 <field id="precip" long_name="Precip Totale liq+sol" unit="kg/(s*m2)" /> 80 <field id="prhmax" field_ref="precip" operation="maximum" />81 <field id="rain_fall" long_name="Precip Totale liq" unit="kg/(s*m2)" />82 <field id="rain_con" long_name="Precip convective liq" unit="kg/(s*m2)" />83 71 <field id="plul" long_name="Large-scale Precip." unit="kg/(s*m2)" /> 84 72 <field id="plun" long_name="Numerical Precip." unit="kg/(s*m2)" /> … … 98 86 <field id="SWupTOA" long_name="SWup at TOA" unit="W/m2" /> 99 87 <field id="SWupTOAclr" long_name="SWup clear sky at TOA" unit="W/m2" /> 100 <field id="SWupTOAcleanclr" long_name="SWup clean (no aerosol) clear sky at TOA" unit="W/m2" />101 88 <field id="SWdnTOA" long_name="SWdn at TOA" unit="W/m2" /> 102 89 <field id="SWdnTOAclr" long_name="SWdn clear sky at TOA" unit="W/m2" /> … … 117 104 <field id="SWupSFC" long_name="SWup at surface" unit="W/m2" /> 118 105 <field id="SWupSFCclr" long_name="SWup clear sky at surface" unit="W/m2" /> 119 <field id="SWupSFCcleanclr" long_name="SWup clean (no aerosol) clear sky at surface" unit="W/m2" />120 106 <field id="SWdnSFC" long_name="SWdn at surface" unit="W/m2" /> 121 107 <field id="SWdnSFCclr" long_name="SWdn clear sky at surface" unit="W/m2" /> 122 <field id="SWdnSFCcleanclr" long_name="SWdn clean (no aerosol) clear sky at surface" unit="W/m2" />123 108 <field id="LWupSFC" long_name="Upwd. IR rad. at surface" unit="W/m2" /> 124 109 <field id="LWupSFCclr" long_name="CS Upwd. IR rad. at surface" unit="W/m2" /> 125 <field id="LWupTOAcleanclr" long_name="CS clean (no aerosol) Upwd. IR rad. at TOA" unit="W/m2" />126 110 <field id="LWdnSFC" long_name="Down. IR rad. at surface" unit="W/m2" /> 127 111 <field id="LWdnSFCclr" long_name="Down. CS IR rad. at surface" unit="W/m2" /> 128 <field id="LWdnSFCcleanclr" long_name="Down. CS clean (no aerosol) IR rad. at surface" unit="W/m2" />129 112 <field id="bils" long_name="Surf. total heat flux" unit="W/m2" /> 130 113 <field id="bils_tke" long_name="Surf. total heat flux" unit="W/m2" /> … … 135 118 <field id="bils_latent" long_name="Surf. total heat flux" unit="W/m2" /> 136 119 <field id="bils_ech" long_name="peu importe" unit="W/m2" /> 120 <field id="du_gwd_rando" long_name="peu importe" unit="W/m2" /> 121 <field id="dv_gwd_rando" long_name="peu importe" unit="W/m2" /> 137 122 <field id="ustr_gwd_hines" long_name="zonal wind stress Hines gravity waves" unit="Pa" /> 138 123 <field id="vstr_gwd_hines" long_name="meridional wind stress Hines gravity waves" unit="Pa" /> … … 159 144 <field id="fqfonte" long_name="Land ice melt" unit="kg/m2/s" /> 160 145 <field id="runofflic" long_name="Land ice melt to ocean" unit="kg/m2/s" /> 161 <field id="mrroli" long_name="Runoff flux over land ice" unit="kg/m2/s" />162 146 <field id="taux" long_name="Zonal wind stress" unit="Pa" /> 163 147 <field id="tauy" long_name="Meridional wind stress" unit="Pa" /> … … 235 219 <field id="uq" long_name="Zonal humidity transport" unit="-" /> 236 220 <field id="vq" long_name="Merid humidity transport" unit="-" /> 237 <field id="uwat" long_name="Zonal total water transport" unit="-" />238 <field id="vwat" long_name="Merid total water transport" unit="-" />239 221 <field id="cape" long_name="Conv avlbl pot ener" unit="J/kg" /> 240 222 <field id="pbase" long_name="Cld base pressure" unit="Pa" /> … … 265 247 <field id="proba_notrig" long_name="Probabilite de non-declenchement" unit="-" /> 266 248 <field id="random_notrig" long_name="Tirage aleatoire de non-declenchement" unit="-" /> 267 <field id="cv_gen" long_name="Cumulonimbus genesis" unit="1/(m2 s)" />268 249 <field id="ale_bl_stat" long_name="ALE_BL_STAT" unit="m2/s2" /> 269 250 <field id="ale_bl_trig" long_name="ALE_BL_STAT + Condition P>Pseuil" unit="m2/s2" /> … … 327 308 <field id="v10_sic" long_name="-" unit="-" /> 328 309 <field id="rh2m" long_name="Relative humidity at 2m" unit="%" /> 329 <field id="rh2m_max" field_ref="rh2m" operation="maximum" /> 330 <field id="rh2m_min" field_ref="rh2m" operation="minimum" /> 331 <!-- <field id="rh2m_min" long_name="Min Relative humidity at 2m" unit="%" /> --> 332 <!-- <field id="rh2m_max" long_name="Max Relative humidity at 2m" unit="%" /> --> 310 <field id="rh2m_min" long_name="Min Relative humidity at 2m" unit="%" /> 311 <field id="rh2m_max" long_name="Max Relative humidity at 2m" unit="%" /> 333 312 <field id="qsat2m" long_name="Saturant humidity at 2m" unit="%" /> 334 313 <field id="tpot" long_name="Surface air potential temperature" unit="K" /> 335 314 <field id="tpote" long_name="Surface air equivalent potential temperature" unit="K" /> 336 315 <field id="SWnetOR" long_name="Sfce net SW radiation OR" unit="W/m2" /> 316 <field id="SWdownOR" long_name="Sfce incident SW radiation OR" unit="W/m2" /> 337 317 <field id="LWdownOR" long_name="Sfce incident LW radiation OR" unit="W/m2" /> 338 318 <field id="snowl" long_name="Solid Large-scale Precip." unit="kg/(m2*s)" /> … … 458 438 <field id="alb2" long_name="Surface Near IR albedo" unit="-" /> 459 439 <field id="ftime_con" long_name="Fraction of time convection Occurs" unit="-" /> 460 <field id="ftime_deepcv" long_name="Fraction of time deep convection Occurs" unit="-" /> 461 <field id="wake_h" long_name="wake height" unit="m" /> 462 <field id="wake_dens" long_name="number of wakes per m2" unit="1/m2" /> 440 <field id="wake_h" long_name="wake_h" unit="-" /> 463 441 <field id="wake_s" long_name="wake_s" unit="-" /> 464 442 <field id="epmax" long_name="epmax en fn cape" unit="su" /> … … 543 521 <field id="ocond" long_name="Condensed water" unit="kg/kg" /> 544 522 <field id="geop" long_name="Geopotential height" unit="m2/s2" /> 545 <field id="geoph" field_ref="geop" long_name="Geopotential height" unit="m" > geop/9.80665 </field>546 523 <field id="vitu" long_name="Zonal wind" unit="m/s" /> 547 524 <field id="vitv" long_name="Meridional wind" unit="m/s" /> … … 578 555 <field id="lcc3dcon" long_name="Convective cloud liquid fraction" unit="1" /> 579 556 <field id="lcc3dstra" long_name="Stratiform cloud liquid fraction" unit="1" /> 580 <field id="cldwatmxrat" long_name="Cloud Water Mixing Ratio" unit="1" />581 <field id="icc3dcon" long_name="Mass Fraction of Convective Cloud Ice" unit="kg/kg" />582 <field id="icc3dstra" long_name="Mass Fraction of Stratiform Cloud Ice " unit="kg/kg" />583 <field id="cldicemxrat" long_name="Cloud Ice Mixing Ratio" unit="1" />584 557 <field id="clwcon" long_name="Convective Cloud Liquid water content" unit="kg/kg" /> 585 558 <field id="Ma" long_name="undilute adiab updraft" unit="kg/m2/s" /> … … 655 628 <field id="dulif" long_name="Orography dU" unit="m/s2" /> 656 629 <field id="dvlif" long_name="Orography dV" unit="m/s2" /> 657 <field id="du_gwd_rando" long_name="peu importe" unit="W/m2" />658 <field id="dv_gwd_rando" long_name="peu importe" unit="W/m2" />659 630 <field id="du_gwd_hines" long_name="Hines GWD dU" unit="m/s2" /> 660 631 <field id="dv_gwd_hines" long_name="Hines GWD dV" unit="m/s2" /> … … 666 637 <field id="dtlif" long_name="Orography dT" unit="K/s" /> 667 638 <field id="dthin" long_name="Hines GWD dT" unit="K/s" /> 668 <field id="rsu" long_name="SW upward radiation" unit="W m-2" /> 669 <field id="rsd" long_name="SW downward radiation" unit="W m-2" /> 670 <field id="rlu" long_name="LW upward radiation" unit="W m-2" /> 671 <field id="rld" long_name="LW downward radiation" unit="W m-2" /> 672 <field id="rsucsaf" long_name="SW clean (no aerosol) CS upward radiation" unit="W m-2" /> 673 <field id="rsdcsaf" long_name="SW clean (no aerosol) CS downward radiation" unit="W m-2" /> 674 <field id="rsucs" long_name="SW CS upward radiation" unit="W m-2" /> 675 <field id="rsdcs" long_name="SW CS downward radiation" unit="W m-2" /> 676 <field id="rlucs" long_name="LW CS upward radiation" unit="W m-2" /> 677 <field id="rldcs" long_name="LW CS downward radiation" unit="W m-2" /> 639 <field id="rsu" long_name="SW upward radiation" unit="W m-2" enabled="FALSE" /> 640 <field id="rsd" long_name="SW downward radiation" unit="W m-2" enabled="FALSE" /> 641 <field id="rlu" long_name="LW upward radiation" unit="W m-2" enabled="FALSE" /> 642 <field id="rld" long_name="LW downward radiation" unit="W m-2" enabled="FALSE" /> 643 <field id="rsucs" long_name="SW CS upward radiation" unit="W m-2" enabled="FALSE" /> 644 <field id="rsdcs" long_name="SW CS downward radiation" unit="W m-2" enabled="FALSE" /> 645 <field id="rlucs" long_name="LW CS upward radiation" unit="W m-2" enabled="FALSE" /> 646 <field id="rldcs" long_name="LW CS downward radiation" unit="W m-2" enabled="FALSE" /> 678 647 <field id="tnt" long_name="Tendency of air temperature" unit="K s-1" /> 679 648 <field id="tntc" long_name="Tendency of air temperature due to Moist Convection" unit="K s-1" /> … … 698 667 <field id="rldcs4co2" long_name="Downwelling CS LW 4xCO2 atmosphere" unit="W/m2" /> 699 668 <field id="stratomask" long_name="Stratospheric fraction" unit="-" /> 700 <field id="pvap" long_name="pvap intermediary variable" unit="-">pres*ovap*461.5 / (287.04*(1.+ (10.9491/18.0153)*ovap)) </field>701 669 </field_group> 702 670 … … 724 692 <field id="OD1020_strat_only" long_name="Stratospheric Aerosol Optical depth at 1020 nm " unit="1" /> 725 693 <field id="surf_PM25_sulf" long_name="Sulfate PM2.5 concentration at the surface" unit="ug/m3" /> 726 <field id="budg_dep_dry_ocs" long_name="OCS dry deposition flux" unit="kg(S)/m2/s" />727 <field id="budg_dep_wet_ocs" long_name="OCS wet deposition flux" unit="kg(S)/m2/s" />728 <field id="budg_dep_dry_so2" long_name="SO2 dry deposition flux" unit="kg(S)/m2/s" />729 <field id="budg_dep_wet_so2" long_name="SO2 wet deposition flux" unit="kg(S)/m2/s" />730 694 <field id="budg_dep_dry_h2so4" long_name="H2SO4 dry deposition flux" unit="kg(S)/m2/s" /> 731 695 <field id="budg_dep_wet_h2so4" long_name="H2SO4 wet deposition flux" unit="kg(S)/m2/s" /> … … 819 783 </field_group> 820 784 821 <field_group id="fields_solbnd_3D" grid_ref="grid_glo_spectband" > 822 <field id="solbnd" long_name="Top-of-Atmosphere Solar Insolation for each band" unit="W m-2" /> 823 </field_group> 824 825 <field_group id="fields_COSP_CALIPSO_2D" grid_ref="grid_glo" freq_offset="0ts" freq_op="3h"> 785 <field_group id="fields_COSP_CALIPSO_2D" grid_ref="grid_glo" freq_op="3h"> 826 786 <field id="cllcalipso" long_name="Lidar Low-level Cloud Fraction" unit="1" detect_missing_value=".true." /> 827 787 <field id="clhcalipso" long_name="Lidar Hight-level Cloud Fraction" unit="1" detect_missing_value=".true." /> 828 788 <field id="clmcalipso" long_name="Lidar Mid-level Cloud Fraction" unit="1" detect_missing_value=".true." /> 829 789 <field id="cltcalipso" long_name="Lidar Total Cloud Fraction" unit="1" detect_missing_value=".true." /> 830 <field id="pcllcalipso" long_name="Lidar Low-level Cloud Fraction" unit="%" detect_missing_value=".true." > cllcalipso*100 </field>831 <field id="pclhcalipso" long_name="Lidar Hight-level Cloud Fraction" unit="%" detect_missing_value=".true." > clhcalipso*100 </field>832 <field id="pclmcalipso" long_name="Lidar Mid-level Cloud Fraction" unit="%" detect_missing_value=".true." > clmcalipso*100 </field>833 <field id="pcltcalipso" long_name="Lidar Total Cloud Fraction" unit="%" detect_missing_value=".true." > cltcalipso*100 </field>790 <field id="pcllcalipso" field_ref="cllcalipso" long_name="Lidar Low-level Cloud Fraction" unit="%" detect_missing_value=".true." > cllcalipso*100 </field> 791 <field id="pclhcalipso" field_ref="clhcalipso" long_name="Lidar Hight-level Cloud Fraction" unit="%" detect_missing_value=".true." > clhcalipso*100 </field> 792 <field id="pclmcalipso" field_ref="clmcalipso" long_name="Lidar Mid-level Cloud Fraction" unit="%" detect_missing_value=".true." > clmcalipso*100 </field> 793 <field id="pcltcalipso" field_ref="cltcalipso" long_name="Lidar Total Cloud Fraction" unit="%" detect_missing_value=".true." > cltcalipso*100 </field> 834 794 <field id="cllcalipsoice" long_name="Lidar Ice-Phase Low-level Cloud Fraction" unit="1" detect_missing_value=".true." /> 835 795 <field id="clhcalipsoice" long_name="Lidar Ice-Phase Hight-level Cloud Fraction" unit="1" detect_missing_value=".true." /> … … 848 808 <field id="clzopaquecalipso" long_name="Lidar mean altitude of opacity" unit="m" detect_missing_value=".true." /> 849 809 </field_group> 850 <field_group id="fields_COSP_CALIPSO_3D_height" grid_ref="grid_glo_height" freq_o ffset="0ts" freq_op="3h">810 <field_group id="fields_COSP_CALIPSO_3D_height" grid_ref="grid_glo_height" freq_op="3h"> 851 811 <field id="clcalipso" long_name="Lidar Cloud Fraction (532 nm)" unit="1" detect_missing_value=".true." /> 852 <field id="pclcalipso" long_name="Lidar Cloud Fraction (532 nm)" unit="%" detect_missing_value=".true." > clcalipso*100 </field>812 <field id="pclcalipso" field_ref="clcalipso" long_name="Lidar Cloud Fraction (532 nm)" unit="%" detect_missing_value=".true." > clcalipso*100 </field> 853 813 <field id="clcalipsoice" long_name="Lidar Ice-Phase Cloud Fraction (532 nm)" unit="1" detect_missing_value=".true." /> 854 814 <field id="clcalipsoliq" long_name="Lidar Liq-Phase Cloud Fraction (532 nm)" unit="1" detect_missing_value=".true." /> … … 860 820 <field id="proftemp" long_name="Temperature profile (40 lev)" unit="K" detect_missing_value=".true." /> 861 821 </field_group> 862 <field_group id="fields_COSP_CALIPSO_3D_heightmlev" grid_ref="grid_glo_heightmlev" freq_o ffset="0ts" freq_op="3h">822 <field_group id="fields_COSP_CALIPSO_3D_heightmlev" grid_ref="grid_glo_heightmlev" freq_op="3h"> 863 823 <field id="beta_mol532" long_name="Lidar Molecular Backscatter (532 nm)" unit="m-1 sr-1" detect_missing_value=".true." /> 864 824 </field_group> 865 <field_group id="fields_COSP_CALIPSO_3D_temp" grid_ref="grid_glo_temp" freq_o ffset="0ts" freq_op="3h">825 <field_group id="fields_COSP_CALIPSO_3D_temp" grid_ref="grid_glo_temp" freq_op="3h"> 866 826 <field id="clcalipsotmp" long_name="Lidar Cloud Fraction (532 nm)" unit="%" detect_missing_value=".true." /> 867 827 <field id="clcalipsotmpliq" long_name="Lidar Liq-Phase Cloud Fraction (532 nm)" unit="1" detect_missing_value=".true." /> … … 869 829 <field id="clcalipsotmpun" long_name="Undefined-Phase Total Cloud Fraction" unit="1" detect_missing_value=".true." /> 870 830 </field_group> 871 <field_group id="fields_COSP_CALIPSO_3D_sza" grid_ref="grid_glo_sza" freq_o ffset="0ts" freq_op="3h">831 <field_group id="fields_COSP_CALIPSO_3D_sza" grid_ref="grid_glo_sza" freq_op="3h"> 872 832 <field id="parasol_refl" long_name="PARASOL-like mono-directional reflectance" unit="1" detect_missing_value=".true." /> 873 833 <field id="parasol_crefl" long_name="PARASOL-like mono-directional reflectance (integral)" unit="1" detect_missing_value=".true." /> 874 834 <field id="Ncrefl" long_name="Nb for PARASOL-like mono-directional reflectance" unit="1" detect_missing_value=".true." /> 875 835 </field_group> 876 <field id="cfad_lidarsr532" long_name="Lidar Scattering Ratio CFAD (532 nm)" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dsrbin" detect_missing_value=".true." />877 <field id="atb532" long_name="Lidar Attenuated Total Backscatter (532 nm)" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dcol" detect_missing_value=".true." />878 <field id="profSR" long_name="Scattering Ratio profiles" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dcol2" detect_missing_value=".true." />879 880 <field_group id="fields_COSP_CLOUDSAT_2D" grid_ref="grid_glo" freq_o ffset="0ts" freq_op="3h">836 <field id="cfad_lidarsr532" long_name="Lidar Scattering Ratio CFAD (532 nm)" unit="1" freq_op="3h" grid_ref="grid4Dsrbin" detect_missing_value=".true." /> 837 <field id="atb532" long_name="Lidar Attenuated Total Backscatter (532 nm)" unit="1" freq_op="3h" grid_ref="grid4Dcol" detect_missing_value=".true." /> 838 <field id="profSR" long_name="Scattering Ratio profiles" unit="1" freq_op="3h" grid_ref="grid4Dcol2" detect_missing_value=".true." /> 839 840 <field_group id="fields_COSP_CLOUDSAT_2D" grid_ref="grid_glo" freq_op="3h"> 881 841 <field id="cltlidarradar" long_name="Lidar and Radar Total Cloud Fraction" unit="1" detect_missing_value=".true." /> 882 842 </field_group> 883 <field_group id="fields_COSP_CLOUDSAT_3D" grid_ref="grid_glo_height" freq_o ffset="0ts" freq_op="3h">843 <field_group id="fields_COSP_CLOUDSAT_3D" grid_ref="grid_glo_height" freq_op="3h"> 884 844 <field id="clcalipso2" long_name="CALIPSO Cloud Fraction Undetected by CloudSat" unit="1" detect_missing_value=".true." /> 885 845 </field_group> 886 <field id="dbze94" long_name="CloudSat Radar Reflectivity" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dcol" detect_missing_value=".true." />887 <field id="cfadDbze94" long_name="CloudSat Radar Reflectivity CFAD" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Ddbze" detect_missing_value=".true." />888 889 <field_group id="fields_COSP_ISCCP_2D" grid_ref="grid_glo" freq_o ffset="0ts" freq_op="3h">846 <field id="dbze94" long_name="CloudSat Radar Reflectivity" unit="1" freq_op="3h" grid_ref="grid4Dcol" detect_missing_value=".true." /> 847 <field id="cfadDbze94" long_name="CloudSat Radar Reflectivity CFAD" unit="1" freq_op="3h" grid_ref="grid4Ddbze" detect_missing_value=".true." /> 848 849 <field_group id="fields_COSP_ISCCP_2D" grid_ref="grid_glo" freq_op="3h"> 890 850 <field id="sunlit" long_name="1 for day points, 0 for nightime" unit="1" detect_missing_value=".true." /> 891 851 <field id="tclisccp" long_name="Total Cloud Fraction as Calculated by the ISCCP Simulator" unit="1" detect_missing_value=".true." /> … … 896 856 <field id="meantbclrisccp" long_name="Mean clear-sky 10.5 micron brightness temperature as calculated by the ISCCP Simulator" unit="K" detect_missing_value=".true." /> 897 857 </field_group> 898 <field_group id="fields_COSP_ISCCP_3D" grid_ref="grid_glo_column" freq_o ffset="0ts" freq_op="3h">858 <field_group id="fields_COSP_ISCCP_3D" grid_ref="grid_glo_column" freq_op="3h"> 899 859 <field id="boxtauisccp" long_name="Optical Depth in Each Column as Calculated by the ISCCP Simulator" unit="1" detect_missing_value=".true." /> 900 860 <field id="boxptopisccp" long_name="Cloud Top Pressure in Each Column as Calculated by the ISCCP Simulator" unit="Pa" detect_missing_value=".true." /> 901 861 </field_group> 902 <field id="clisccp2" long_name="Cloud Fraction as Calculated by the ISCCP Simulator" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dtau" detect_missing_value=".true." />903 904 <field_group id="fields_COSP_MISR" freq_o ffset="0ts" freq_op="3h">862 <field id="clisccp2" long_name="Cloud Fraction as Calculated by the ISCCP Simulator" unit="1" freq_op="3h" grid_ref="grid4Dtau" detect_missing_value=".true." /> 863 864 <field_group id="fields_COSP_MISR" freq_op="3h"> 905 865 <field id="clMISR" long_name="Cloud Fraction as Calculated by the MISR Simulator" unit="1" grid_ref="grid4Dmisr" detect_missing_value=".true." /> 906 866 </field_group> 907 867 908 <field_group id="fields_COSP_MODIS" grid_ref="grid_glo" freq_offset="0ts"freq_op="3h">868 <field_group id="fields_COSP_MODIS" grid_ref="grid_glo" freq_op="3h"> 909 869 <field id="cllmodis" long_name="MODIS Low-level Cloud Fraction" unit="1" detect_missing_value=".true." /> 910 870 <field id="clmmodis" long_name="MODIS Mid-level Cloud Fraction" unit="1" detect_missing_value=".true." /> … … 925 885 <field id="iwpmodis" long_name="Modis Ice_Water_Path_Mean" unit="kg m-2" detect_missing_value=".true." /> 926 886 </field_group> 927 <field id="clmodis" long_name="MODIS Cloud Area Fraction" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dtau" detect_missing_value=".true." />928 <field id="crimodis" long_name="MODIS Optical_Thickness_vs_ReffIce" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dreffi" detect_missing_value=".true." />929 <field id="crlmodis" long_name="MODIS Optical_Thickness_vs_ReffLiq" unit="1" freq_o ffset="0ts" freq_op="3h" grid_ref="grid4Dreffl" detect_missing_value=".true." />887 <field id="clmodis" long_name="MODIS Cloud Area Fraction" unit="1" freq_op="3h" grid_ref="grid4Dtau" detect_missing_value=".true." /> 888 <field id="crimodis" long_name="MODIS Optical_Thickness_vs_ReffIce" unit="1" freq_op="3h" grid_ref="grid4Dreffi" detect_missing_value=".true." /> 889 <field id="crlmodis" long_name="MODIS Optical_Thickness_vs_ReffLiq" unit="1" freq_op="3h" grid_ref="grid4Dreffl" detect_missing_value=".true." /> 930 890 931 891 <field_group id="fields_AIRS" grid_ref="grid_glo" operation="instant" freq_op="3h"> … … 975 935 <field id="CFC11_ppt" long_name="CFC11_ppt" unit="ppt" /> 976 936 <field id="CFC12_ppt" long_name="CFC12_ppt" unit="ppt" /> 977 <!-- reducing mass 3D variable to atmosphere total mass scalar -->978 <field id="mass_sum" field_ref="mass" grid_ref="grid_sum" grid_path="grid_sum_axis" freq_op="1mo" > @mass </field>979 937 </field_group> 980 938
Note: See TracChangeset
for help on using the changeset viewer.