Ignore:
Timestamp:
May 9, 2012, 3:14:48 PM (13 years ago)
Author:
lguez
Message:

Created logical variable "pressure_exner". "pressure_exner" replaces
"disvert_type" to choose between calls to "exner_hyb" and
"exner_milieu". If "pressure_exner" is true, pressure inside layers is
computed from Exner function ("exner_hyb"), else it is the mean of
pressure values at interfaces ("exner_milieu"). "disvert_type" now
only chooses between "disvert" and "disvert_noterre". Default value
for "pressure_exner" is true if "disvert_type" equals 1.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • LMDZ5/trunk/libf/dyn3d/exner_hyb.F

    r1520 r1625  
    5656      ! Sanity check
    5757      if (firstcall) then
    58         ! check that vertical discretization is compatible
    59         ! with this routine
    60         if (disvert_type.ne.1) then
    61           call abort_gcm(modname,
    62      &     "this routine should only be called if disvert_type==1",42)
    63         endif
    64        
    6558        ! sanity checks for Shallow Water case (1 vertical layer)
    6659        if (llm.eq.1) then
Note: See TracChangeset for help on using the changeset viewer.