source: LMDZ6/trunk/libf/dyn3d/advtrac.F90 @ 4129

Last change on this file since 4129 was 4064, checked in by dcugnet, 3 years ago
  • minor fixes (unused variables suppressed, comas after a WRITE() statement, etc.)
  • parser routines taken from version 7 of https://svn.lmd.jussieu.fr/tracers-parser
  • few changes in infotrac, and few fixes of (at least) the sequential version:
    • uadv and vadv were deallocated twice (fix was lost by mistake just before last commit)
    • in [( dum(im), im=1, nm)] implicit loops, ifort evaluates "dum(im)" even if nm==0,

resulting in a crash, "im" being unitialized.

  • Property copyright set to
    Name of program: LMDZ
    Creation date: 1984
    Version: LMDZ5
    License: CeCILL version 2
    Holder: Laboratoire de m\'et\'eorologie dynamique, CNRS, UMR 8539
    See the license file in the root directory
  • Property svn:eol-style set to native
  • Property svn:keywords set to Author Date Id Revision
File size: 14.3 KB
RevLine 
[1279]1! $Id: advtrac.F90 4064 2022-01-25 18:14:39Z fairhead $
[1146]2
[4056]3#define DEBUG_IO
4#undef DEBUG_IO
5SUBROUTINE advtrac(pbaru, pbarv, p, masse,q,iapptrac,teta, flxw, pk)
6   !     Auteur :  F. Hourdin
7   !
8   !     Modif. P. Le Van     (20/12/97)
9   !            F. Codron     (10/99)
10   !            D. Le Croller (07/2001)
11   !            M.A Filiberti (04/2002)
12   !
13   USE infotrac,     ONLY: nqtot, tracers,ok_iso_verif
14   USE control_mod,  ONLY: iapp_tracvl, day_step
15   USE comconst_mod, ONLY: dtvr
[524]16
[4056]17   IMPLICIT NONE
18   !
19   include "dimensions.h"
20   include "paramet.h"
21   include "comdissip.h"
22   include "comgeom2.h"
23   include "description.h"
24   include "iniprint.h"
[524]25
[4056]26   !---------------------------------------------------------------------------
27   !     Arguments
28   !---------------------------------------------------------------------------
29   INTEGER, INTENT(OUT) :: iapptrac
30   REAL, INTENT(IN) :: pbaru(ip1jmp1,llm)
31   REAL, INTENT(IN) :: pbarv(ip1jm,  llm)
32   REAL, INTENT(INOUT) ::  q(ip1jmp1,llm,nqtot)
33   REAL, INTENT(IN) :: masse(ip1jmp1,llm)
34   REAL, INTENT(IN) ::     p(ip1jmp1,llmp1 )
35   REAL, INTENT(IN) ::  teta(ip1jmp1,llm)
36   REAL, INTENT(IN) ::    pk(ip1jmp1,llm)
37   REAL, INTENT(OUT) :: flxw(ip1jmp1,llm)
38   !---------------------------------------------------------------------------
39   !     Ajout PPM
40   !---------------------------------------------------------------------------
41   REAL :: massebx(ip1jmp1,llm), masseby(ip1jm,llm)
42   !---------------------------------------------------------------------------
43   !     Variables locales
44   !---------------------------------------------------------------------------
[4064]45   INTEGER :: ij, l, iq, iadv
46!   REAL(KIND=KIND(1.d0)) :: t_initial, t_final, tps_cpu
[4056]47   REAL :: zdp(ip1jmp1), zdpmin, zdpmax
48   INTEGER, SAVE :: iadvtr=0
49   REAL, DIMENSION(ip1jmp1,llm) :: pbaruc, pbarug, massem, wg
50   REAL, DIMENSION(ip1jm,  llm) :: pbarvc, pbarvg
51   EXTERNAL  minmax
52   SAVE massem, pbaruc, pbarvc
53   !---------------------------------------------------------------------------
54   !     Rajouts pour PPM
55   !---------------------------------------------------------------------------
56   INTEGER indice, n
57   REAL :: dtbon                       ! Pas de temps adaptatif pour que CFL<1
58   REAL :: CFLmaxz, aaa, bbb           ! CFL maximum
59   REAL, DIMENSION(iim,jjp1,llm) :: unatppm, vnatppm, fluxwppm
60   REAL ::    qppm(iim*jjp1,llm,nqtot)
61   REAL ::   psppm(iim,jjp1)           ! pression  au sol
62   REAL, DIMENSION(llmp1) :: apppm, bpppm
63   LOGICAL, SAVE :: dum=.TRUE., fill=.TRUE.
[524]64
[4056]65   INTEGER, SAVE :: countcfl=0
66   REAL, DIMENSION(ip1jmp1,llm) :: cflx, cflz
67   REAL, DIMENSION(ip1jm  ,llm) :: cfly
68   REAL, DIMENSION(llm), SAVE :: cflxmax, cflymax, cflzmax
[524]69
[4056]70   IF(iadvtr == 0) THEN
71      pbaruc(:,:)=0
72      pbarvc(:,:)=0
73   END IF
[524]74
[4056]75   !--- Accumulation des flux de masse horizontaux
76   DO l=1,llm
77      DO ij = 1,ip1jmp1
78         pbaruc(ij,l) = pbaruc(ij,l) + pbaru(ij,l)
79      END DO
80      DO ij = 1,ip1jm
81         pbarvc(ij,l) = pbarvc(ij,l) + pbarv(ij,l)
82      END DO
83   END DO
[524]84
[4056]85   !--- Selection de la masse instantannee des mailles avant le transport.
86   IF(iadvtr == 0) THEN
[1549]87     CALL SCOPY(ip1jmp1*llm,masse,1,massem,1)
[4056]88   ! CALL filtreg ( massem ,jjp1, llm,-2, 2, .TRUE., 1 )
89   END IF
[524]90
[4056]91   iadvtr   = iadvtr+1
92   iapptrac = iadvtr
[524]93
[4056]94   !--- Test pour savoir si on advecte a ce pas de temps
95   IF(iadvtr /= iapp_tracvl) RETURN
[524]96
[4056]97   !   ..  Modif P.Le Van  ( 20/12/97 )  ....
98   !
99   !   traitement des flux de masse avant advection.
100   !       1. calcul de w
101   !       2. groupement des mailles pres du pole.
[524]102
[4056]103   CALL groupe(massem, pbaruc, pbarvc, pbarug, pbarvg, wg)
[524]104
[4056]105   !--- Flux de masse diaganostiques traceurs
106   flxw = wg / REAL(iapp_tracvl)
[524]107
[4056]108   !--- Test sur l'eventuelle creation de valeurs negatives de la masse
109   DO l=1,llm-1
110      DO ij = iip2+1,ip1jm
111         zdp(ij) = pbarug(ij-1,l)    - pbarug(ij,l) &
112                 - pbarvg(ij-iip1,l) + pbarvg(ij,l) &
113                 +     wg(ij,l+1)    -     wg(ij,l)
114      END DO
115! ym  ---> pourquoi jjm-1 et non jjm ? a cause du pole ?
116      CALL SCOPY( jjm -1 ,zdp(iip1+iip1),iip1,zdp(iip2),iip1 )
117      DO ij = iip2,ip1jm
118         zdp(ij)= zdp(ij)*dtvr/ massem(ij,l)
119      END DO
[524]120
[4056]121      CALL minmax ( ip1jm-iip1, zdp(iip2), zdpmin,zdpmax )
[524]122
[4056]123      IF(MAX(ABS(zdpmin),ABS(zdpmax)) > 0.5) &
124         WRITE(*,*)'WARNING DP/P l=',l,'  MIN:',zdpmin,' MAX:', zdpmax
[524]125
[4056]126   END DO
[524]127
[4056]128   !-------------------------------------------------------------------------
129   ! Calcul des criteres CFL en X, Y et Z
130   !-------------------------------------------------------------------------
131   IF(countcfl == 0. ) then
132      cflxmax(:)=0.
133      cflymax(:)=0.
134      cflzmax(:)=0.
135   END IF
[524]136
[4056]137   countcfl=countcfl+iapp_tracvl
138   cflx(:,:)=0.
139   cfly(:,:)=0.
140   cflz(:,:)=0.
141   DO l=1,llm
142      DO ij=iip2,ip1jm-1
143         IF(pbarug(ij,l)>=0.) then
144            cflx(ij,l)=pbarug(ij,l)*dtvr/masse(ij,l)
145         ELSE
146            cflx(ij,l)=-pbarug(ij,l)*dtvr/masse(ij+1,l)
147         END IF
148      END DO
149   END DO
[1279]150
[4056]151   DO l=1,llm
152      DO ij=iip2,ip1jm-1,iip1
153         cflx(ij+iip1,l)=cflx(ij,l)
154      END DO
155   END DO
[1279]156
[4056]157   DO l=1,llm
158      DO ij=1,ip1jm
159         IF(pbarvg(ij,l)>=0.) then
160            cfly(ij,l)=pbarvg(ij,l)*dtvr/masse(ij,l)
161         ELSE
162            cfly(ij,l)=-pbarvg(ij,l)*dtvr/masse(ij+iip1,l)
163         END IF
164      END DO
165   END DO
[1279]166
[4056]167   DO l=2,llm
168      DO ij=1,ip1jm
169         IF(wg(ij,l) >= 0.) THEN
170            cflz(ij,l)=wg(ij,l)*dtvr/masse(ij,l)
171         ELSE
172            cflz(ij,l)=-wg(ij,l)*dtvr/masse(ij,l-1)
173         END IF
174      END DO
175   END DO
[1279]176
[4056]177   DO l=1,llm
178      cflxmax(l)=max(cflxmax(l),maxval(cflx(:,l)))
179      cflymax(l)=max(cflymax(l),maxval(cfly(:,l)))
180      cflzmax(l)=max(cflzmax(l),maxval(cflz(:,l)))
181   END DO
[1279]182
[4056]183   !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
184   ! Par defaut, on sort le diagnostic des CFL tous les jours.
185   ! Si on veut le sortir a chaque pas d'advection en cas de plantage
186   !       IF(countcfl==iapp_tracvl) then
187   !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
188   IF(countcfl==day_step) then
189      DO l=1,llm
190         WRITE(lunout,*) 'L, CFL[xyz]max:', l, cflxmax(l), cflymax(l), cflzmax(l)
191      END DO
192      countcfl=0
193   END IF
[1279]194
[4056]195   !---------------------------------------------------------------------------
196   !   Advection proprement dite (Modification Le Croller (07/2001)
197   !---------------------------------------------------------------------------
[1279]198
[4056]199   !---------------------------------------------------------------------------
200   !   Calcul des moyennes basees sur la masse
201   !---------------------------------------------------------------------------
202   CALL massbar(massem,massebx,masseby)
[1549]203
[4056]204#ifdef DEBUG_IO   
205   CALL WriteField_u('massem',massem)
206   CALL WriteField_u('wg',wg)
207   CALL WriteField_u('pbarug',pbarug)
208   CALL WriteField_v('pbarvg',pbarvg)
209   CALL WriteField_u('p_tmp',p)
210   CALL WriteField_u('pk_tmp',pk)
211   CALL WriteField_u('teta_tmp',teta)
212   DO iq=1,nqtot
213      CALL WriteField_u('q_adv'//trim(int2str(iq)),q(:,:,iq))
214   END DO
215#endif
[1549]216
[4056]217   IF(ok_iso_verif) THEN
218      WRITE(*,*) 'advtrac 227'
219      CALL check_isotopes_seq(q,ip1jmp1,'advtrac 162')
220   END IF
[524]221
[4056]222   !-------------------------------------------------------------------------
223   !       Appel des sous programmes d'advection
224   !-------------------------------------------------------------------------
225   DO iq = 1, nqtot
226!     CALL clock(t_initial)
227      IF(tracers(iq)%parent /= 'air') CYCLE
228      iadv = tracers(iq)%iadv
229      !-----------------------------------------------------------------------
230      SELECT CASE(iadv)
231      !-----------------------------------------------------------------------
[4050]232         CASE(0); CYCLE
[4056]233         !--------------------------------------------------------------------
234         CASE(10)  !--- Schema de Van Leer I MUSCL
235         !--------------------------------------------------------------------
236!           WRITE(*,*) 'advtrac 239: iq,q(1721,19,:)=',iq,q(1721,19,:)     
237            CALL vlsplt(q,2.,massem,wg,pbarug,pbarvg,dtvr,iq)
[524]238
[4056]239         !--------------------------------------------------------------------
240         CASE(14)  !--- Schema "pseuDO amont" + test sur humidite specifique
241                   !--- pour la vapeur d'eau. F. Codron
242         !--------------------------------------------------------------------
243!           WRITE(*,*) 'advtrac 248: iq,q(1721,19,:)=',iq,q(1721,19,:)
244            CALL vlspltqs(q,2.,massem,wg,pbarug,pbarvg,dtvr,p,pk,teta,iq)
[960]245
[4056]246         !--------------------------------------------------------------------
247         CASE(12)  !--- Schema de Frederic Hourdin
248         !--------------------------------------------------------------------
249            CALL adaptdt(iadv,dtbon,n,pbarug,massem)   ! pas de temps adaptatif
250            IF(n > 1) WRITE(*,*) 'WARNING horizontal dt=',dtbon,'dtvr=',dtvr,'n=',n
251            DO indice=1,n
252              CALL advn(q(1,1,iq),massem,wg,pbarug,pbarvg,dtbon,1)
253            END DO
[524]254
[4056]255         !--------------------------------------------------------------------
256         CASE(13)  !--- Pas de temps adaptatif
257         !--------------------------------------------------------------------
258            CALL adaptdt(iadv,dtbon,n,pbarug,massem)
259            IF(n > 1) WRITE(*,*) 'WARNING horizontal dt=',dtbon,'dtvr=',dtvr,'n=',n
260            DO indice=1,n
261               CALL advn(q(1,1,iq),massem,wg,pbarug,pbarvg,dtbon,2)
262            END DO
[524]263
[4056]264         !--------------------------------------------------------------------
265         CASE(20)  !--- Schema de pente SLOPES
266         !--------------------------------------------------------------------
267            CALL pentes_ini (q(1,1,iq),wg,massem,pbarug,pbarvg,0)
[524]268
[4056]269         !--------------------------------------------------------------------
270         CASE(30)  !--- Schema de Prather
271         !--------------------------------------------------------------------
272            ! Pas de temps adaptatif
273            CALL adaptdt(iadv,dtbon,n,pbarug,massem)
274            IF(n > 1) WRITE(*,*) 'WARNING horizontal dt=',dtbon,'dtvr=',dtvr,'n=',n
275            CALL prather(q(1,1,iq),wg,massem,pbarug,pbarvg,n,dtbon)
[524]276
[4056]277         !--------------------------------------------------------------------
278         CASE(11,16,17,18)   !--- Schemas PPM Lin et Rood
279         !--------------------------------------------------------------------
280            ! Test sur le flux horizontal
281            CALL adaptdt(iadv,dtbon,n,pbarug,massem)   ! pas de temps adaptatif
282            IF(n > 1) WRITE(*,*) 'WARNING horizontal dt=',dtbon,'dtvr=',dtvr,'n=',n
283            ! Test sur le flux vertical
284            CFLmaxz=0.
285            DO l=2,llm
286               DO ij=iip2,ip1jm
287                  aaa=wg(ij,l)*dtvr/massem(ij,l)
288                  CFLmaxz=max(CFLmaxz,aaa)
289                  bbb=-wg(ij,l)*dtvr/massem(ij,l-1)
290                  CFLmaxz=max(CFLmaxz,bbb)
291               END DO
292            END DO
293            IF(CFLmaxz.GE.1) WRITE(*,*) 'WARNING vertical','CFLmaxz=', CFLmaxz
294            !----------------------------------------------------------------
295            !     Ss-prg interface LMDZ.4->PPM3d (ss-prg de Lin)
296            !----------------------------------------------------------------
297            CALL interpre(q(1,1,iq),qppm(1,1,iq),wg,fluxwppm,massem, &
298                 apppm,bpppm,massebx,masseby,pbarug,pbarvg, &
299                 unatppm,vnatppm,psppm)
[524]300
[4056]301            !----------------------------------------------------------------
302            DO indice=1,n     !--- VL (version PPM) horiz. et PPM vert.
303            !----------------------------------------------------------------
304               SELECT CASE(iadv)
305                  !----------------------------------------------------------
306                  CASE(11)
307                  !----------------------------------------------------------
308                     CALL ppm3d(1,qppm(1,1,iq),psppm,psppm,unatppm,vnatppm,fluxwppm,dtbon, &
309                                2,2,2,1,iim,jjp1,2,llm,apppm,bpppm,0.01,6400000,fill,dum,220.)
310                  !----------------------------------------------------------
311                  CASE(16) !--- Monotonic PPM
312                  !----------------------------------------------------------
313                     CALL ppm3d(1,qppm(1,1,iq),psppm,psppm,unatppm,vnatppm,fluxwppm,dtbon, &
314                                3,3,3,1,iim,jjp1,2,llm,apppm,bpppm,0.01,6400000,fill,dum,220.)
315                  !----------------------------------------------------------
316                  CASE(17) !--- Semi monotonic PPM
317                  !----------------------------------------------------------
318                     CALL ppm3d(1,qppm(1,1,iq),psppm,psppm,unatppm,vnatppm,fluxwppm,dtbon, &
319                                4,4,4,1,iim,jjp1,2,llm,apppm,bpppm,0.01,6400000, fill,dum,220.)
320                  !----------------------------------------------------------
321                  CASE(18) !--- Positive Definite PPM
322                  !----------------------------------------------------------
323                     CALL ppm3d(1,qppm(1,1,iq),psppm,psppm,unatppm,vnatppm,fluxwppm,dtbon, &
324                                5,5,5,1,iim,jjp1,2,llm,apppm,bpppm,0.01,6400000,fill,dum,220.)
325               END SELECT
326            !----------------------------------------------------------------
327            END DO
328            !----------------------------------------------------------------
329            !     Ss-prg interface PPM3d-LMDZ.4
330            !----------------------------------------------------------------
331            CALL interpost(q(1,1,iq),qppm(1,1,iq))
332      !----------------------------------------------------------------------
333      END SELECT
334      !----------------------------------------------------------------------
[524]335
[4056]336      !----------------------------------------------------------------------
337      ! On impose une seule valeur du traceur au pole Sud j=jjm+1=jjp1 et Nord j=1
338      !----------------------------------------------------------------------
339      !  CALL traceurpole(q(1,1,iq),massem)
[524]340
[4056]341      !--- Calcul du temps cpu pour un schema donne
342      !  CALL clock(t_final)
343      !ym  tps_cpu=t_final-t_initial
344      !ym  cpuadv(iq)=cpuadv(iq)+tps_cpu
[524]345
[4056]346   END DO
[524]347
[4056]348   IF(ok_iso_verif) then
349      WRITE(*,*) 'advtrac 402'
350      CALL check_isotopes_seq(q,ip1jmp1,'advtrac 397')
351   END IF
[524]352
[4056]353   !-------------------------------------------------------------------------
354   !   on reinitialise a zero les flux de masse cumules
355   !-------------------------------------------------------------------------
356   iadvtr=0
[524]357
[1549]358END SUBROUTINE advtrac
Note: See TracBrowser for help on using the repository browser.