source: LMDZ6/trunk/DefLists/field_def_lmdz.xml @ 4714

Last change on this file since 4714 was 4608, checked in by acozic, 17 months ago

Add of an output file containing mass flow when offline parameter is to "yes"
this file will be on horizontal grid with vertical level klev
When LMDZ is coupled to Inca, we don't call anymore the routine phystoken if offline=y

Anne Cozic

  • Property copyright set to
    Name of program: LMDZ
    Creation date: 1984
    Version: LMDZ5
    License: CeCILL version 2
    Holder: Laboratoire de m\'et\'eorologie dynamique, CNRS, UMR 8539
    See the license file in the root directory
  • Property svn:keywords set to Id
File size: 83.6 KB
Line 
1<!-- $Id: field_def_lmdz.xml 4608 2023-07-05 10:03:42Z evignon $ -->
2<field_definition level="1" prec="4" operation="average" freq_op="1ts" enabled=".true." default_value="9.96921e+36">
3   
4<!--    <field_group id="fields_1D" grid_ref="vertical">  -->
5<!--        <field id="Ap"   long_name="Hybrid coordinate: pressure part"    unit="Pa" />  -->
6<!--        <field id="Bp"   long_name="Hybrid coordinate: sigma part"    unit="-" />  -->
7<!--        <field id="Alt"  long_name="Pseudo-altitude (for an 8km scale height)"    unit="km" />  -->
8<!--    </field_group>  -->
9
10    <field_group id="remap_expr" level="_reset_" prec="_reset_" operation="_reset_" freq_op="_reset_" enabled="_reset_" default_value="_reset_">
11      <field_group id="remap_1ts" />
12      <field_group id="remap_1800s" />
13      <field_group id="remap_1h" />
14      <field_group id="remap_3h" />
15      <field_group id="remap_6h" />
16      <field_group id="remap_1d" />
17      <field_group id="remap_1mo" />
18    </field_group>
19   
20    <field_group id="coordinates" grid_ref="grid_glo">
21        <field id="io_lon"  />
22        <field id="io_lat"  />
23    </field_group>
24
25    <field_group id="coord_hyb">
26        <field id="Ahyb" long_name="Ahyb at level interface"     axis_ref="klevp1" />
27        <field id="Ahyb_bounds" long_name="" grid_ref="klevp1_bnds" />
28        <field id="Bhyb" long_name="Bhyb at level interface"       axis_ref="klevp1"  />
29        <field id="Bhyb_bounds" long_name=""  grid_ref="klevp1_bnds" />
30        <field id="Ahyb_mid" long_name="Ahyb at the middle of the level"      axis_ref="klev" />
31        <field id="Ahyb_mid_bounds" long_name="" grid_ref="klev_bnds" />
32        <field id="Bhyb_mid" long_name="Bhyb at the middle of the level"       axis_ref="klev"  />
33        <field id="Bhyb_mid_bounds" long_name=""  grid_ref="klev_bnds" />
34    </field_group>
35   
36    <field_group id="fields_2D" grid_ref="grid_glo">
37        <field id="phis"    long_name="Surface geop.height"     unit="m2/s2" />
38        <field id="aire"    long_name="Grid area"               unit="m2"    />
39        <field id="contfracATM"     long_name="% sfce ter+lic"  unit="-"   /> 
40        <field id="contfracOR"      long_name="% sfce terre OR" unit="-" />
41        <field id="sza"     long_name="Solar zenithal angle "   unit="deg" />
42        <field id="flat"    long_name="Latent heat flux"        unit="W/m2" />
43        <field id="slp"     long_name="Sea Level Pressure"      unit="Pa" />
44        <field id="ptstar"  long_name="Air Surface Temperature" unit="K" />
45        <field id="pt0"     long_name="Standard Air Surface Temperature"      unit="K" />
46        <field id="tsol"    long_name="Surface Temperature"     unit="K" />
47        <field id="t2m"        long_name="Temperature 2m" unit="K" />
48        <field id="tasmax"  field_ref="t2m"  operation="maximum" />
49        <field id="tasmin"  field_ref="t2m"  operation="minimum" />
50        <field id="t2m_min"    long_name="Temp 2m min"    unit="K" operation="minimum" />
51        <field id="t2m_max"    long_name="Temp 2m max"    unit="K" operation="maximum" />
52        <field id="t2m_ter"    long_name="Temp 2m ter"    unit="K" />
53        <field id="t2m_max_mon"   long_name="Monthly average max 2m temperature" unit="K" />
54        <field id="t2m_min_mon"   long_name="Monthly average min 2m temperature" unit="K" />
55        <field id="t2m_lic"    long_name="Temp 2m lic"    unit="K" />
56        <field id="t2m_oce"    long_name="Temp 2m oce"    unit="K" />
57        <field id="t2m_sic"    long_name="Temp 2m sic"    unit="K" />
58        <field id="nt2mout"    long_name="nt2m hors intervalle, calc.complet" unit="-" />
59        <field id="nq2mout"    long_name="nq2m hors intervalle, calc. complet" unit="-" />
60        <field id="nu2mout"    long_name="nu2m hors intervalle, calc. complet" unit="-" />
61            <field id="nt2moutfg"  long_name="nt2m hors intervalle, calc. complet/fg" unit="-" />
62            <field id="nq2moutfg"  long_name="nq2m hors intervalle, calc. complet/fg" unit="-" />
63            <field id="nu2moutfg"  long_name="nu2m hors intervalle, calc. complet/fg" unit="-" />
64        <field id="t2m_probsup25"   field_ref="t2m" long_name="Prob. t2m exceeds 25 degC" unit="-"> t2m &gt; 298.15 </field>
65        <field id="t2m_probsup28"   field_ref="t2m" long_name="Prob. t2m exceeds 28 degC" unit="-"> t2m &gt; 301.15 </field>
66        <field id="t2m_probsup30"   field_ref="t2m" long_name="Prob. t2m exceeds 30 degC" unit="-"> t2m &gt; 303.15 </field>
67        <field id="gusts"    long_name="surface gustiness"    unit="m2/s2" />
68        <field id="wind10m"    long_name="10-m wind speed"      unit="m/s" />
69        <field id="wind10max"  long_name="10m wind speed max"   unit="m/s" operation="maximum"/>
70        <field id="wind100m"   long_name="100-m wind speed"      unit="m/s" />
71        <field id="woncfr"   long_name="Onshore Wind Capacity factor"      unit="kW/kW_installed" />
72        <field id="wofcfr"   long_name="Offshore Wind Capacity factor"     unit="kW/kW_installed" />
73        <field id="sfcWindmax" field_ref="wind10m" operation="maximum" />
74        <field id="sicf"    long_name="Sea-ice fraction"        unit="-" />
75        <field id="q2m"     long_name="Specific humidity 2m"    unit="kg/kg" />
76        <field id="ustar"   long_name="Friction velocity"       unit="m/s" />
77        <field id="u10m"    long_name="Vent zonal 10m"          unit="m/s" />
78        <field id="v10m"    long_name="Vent meridien 10m"       unit="m/s" />
79        <field id="psol"    long_name="Surface Pressure"        unit="Pa" />
80        <field id="qsurf"   long_name="Surface Air humidity"    unit="kg/kg" />
81        <field id="ustar_ter"    long_name="Friction velocity ter"    unit="m/s" />
82        <field id="ustar_lic"    long_name="Friction velocity lic"    unit="m/s" />
83        <field id="ustar_oce"    long_name="Friction velocity oce"    unit="m/s" />
84        <field id="ustar_sic"    long_name="Friction velocity sic"    unit="m/s" />
85        <field id="wstar_ter"    long_name="Friction velocity ter"    unit="m/s" />
86        <field id="wstar_lic"    long_name="Friction velocity lic"    unit="m/s" />
87        <field id="wstar_oce"    long_name="Friction velocity oce"    unit="m/s" />
88        <field id="wstar_sic"    long_name="Friction velocity sic"    unit="m/s" />
89        <field id="wstar"       long_name="w* convective velocity "    unit="m/s" />
90        <field id="u10m_ter"    long_name="Vent Zonal 10m ter"    unit="m/s" />
91        <field id="u10m_lic"    long_name="Vent Zonal 10m lic"    unit="m/s" />
92        <field id="u10m_oce"    long_name="Vent Zonal 10m oce"    unit="m/s" />
93        <field id="u10m_sic"    long_name="Vent Zonal 10m sic"    unit="m/s" />
94        <field id="v10m_ter"    long_name="Vent meredien 10m ter"    unit="m/s" />
95        <field id="v10m_lic"    long_name="Vent meredien 10m lic"    unit="m/s" />
96        <field id="v10m_oce"    long_name="Vent meredien 10m oce"    unit="m/s" />
97        <field id="v10m_sic"    long_name="Vent meredien 10m sic"    unit="m/s" />
98        <field id="qsol"        long_name="Soil watter content"         unit="mm" />
99        <field id="JrNt"        long_name="1 if Day 0 if Night"         unit="-" />
100        <field id="cldhjn"      long_name="High-level cloudiness Day"         unit="-" />
101        <field id="cldmjn"      long_name="Mid-level cloudiness Day"         unit="-" />
102        <field id="cldljn"      long_name="Low-level cloudiness Day"         unit="-" />
103        <field id="cldtjn"      long_name="Total cloudiness Day"         unit="-" />
104        <field id="rnebjn"      long_name="Cloud fraction in day"         unit="-" />
105        <field id="ndayrain"    long_name="Number of dayrain(liq+sol)"  unit="-" operation="instant"/>
106        <field id="precip"      long_name="Precip Totale liq+sol"       unit="kg/(s*m2)" />
107        <field id="prhmax"      field_ref="precip" operation="maximum"           />
108        <field id="rain_fall"   long_name="Precip Totale liq"   unit="kg/(s*m2)" />
109        <field id="rain_con"    long_name="Precip convective liq"   unit="kg/(s*m2)" />
110        <field id="plul"    long_name="Large-scale Precip."     unit="kg/(s*m2)" />
111        <field id="plun"    long_name="Numerical Precip."       unit="kg/(s*m2)" />
112        <field id="pluc"    long_name="Convective Precip."      unit="kg/(s*m2)" />
113        <field id="snow"    long_name="Snow fall"               unit="kg/(s*m2)" />
114        <field id="evap"    long_name="Evaporat"                unit="kg/(s*m2)" />
115        <field id="snowerosion"    long_name="blowing snow erosion"                unit="kg/(s*m2)" />
116        <field id="bsfall"    long_name="blowing snow precipitation"                unit="kg/(s*m2)" />
117        <field id="rhosnow_lic"    long_name="snow density lic"                unit="kg/m3" />
118        <field id="ustart_lic"    long_name="ustar threshold for snow erosion"                unit="m/s" />
119        <field id="evap_ter"    long_name="evaporation at surface ter"    unit="kg/(s*m2)" />
120        <field id="evap_lic"    long_name="evaporation at surface lic"    unit="kg/(s*m2)" />
121        <field id="evap_oce"    long_name="evaporation at surface oce"    unit="kg/(s*m2)" />
122        <field id="evap_sic"    long_name="evaporation at surface sic"    unit="kg/(s*m2)" />
123        <field id="msnow"    long_name="Surface snow amount"    unit="kg/m2" />
124        <field id="fsnow"    long_name="Surface snow area fraction"    unit="-" />
125        <field id="tops"    long_name="Solar rad. at TOA"    unit="W/m2" />
126        <field id="tops0"    long_name="CS Solar rad. at TOA"    unit="W/m2" />
127        <field id="topl"    long_name="IR rad. at TOA"    unit="W/m2" />
128        <field id="topl0"    long_name="IR rad. at TOA"    unit="W/m2" />
129        <field id="SWupTOA"    long_name="SWup at TOA"    unit="W/m2" />
130        <field id="SWupTOAclr"    long_name="SWup clear sky at TOA"    unit="W/m2" />
131        <field id="SWupTOAcleanclr"    long_name="SWup clean (no aerosol) clear sky at TOA"    unit="W/m2" />
132        <field id="SWdnTOA"    long_name="SWdn at TOA"    unit="W/m2" />
133        <field id="SWdnTOAclr"    long_name="SWdn clear sky at TOA"    unit="W/m2" />
134        <field id="nettop"    long_name="Net dn radiatif flux at TOA"    unit="W/m2" />
135        <field id="SWup200"    long_name="SWup at 200mb"    unit="W/m2" />
136        <field id="SWup200clr"    long_name="SWup clear sky at 200mb"    unit="W/m2" />
137        <field id="SWdn200"    long_name="SWdn at 200mb"    unit="W/m2" />
138        <field id="SWdn200clr"    long_name="SWdn clear sky at 200mb"    unit="W/m2" />
139        <field id="LWup200"    long_name="LWup at 200mb"    unit="W/m2" />
140        <field id="LWup200clr"    long_name="LWup clear sky at 200mb"    unit="W/m2" />
141        <field id="LWdn200"    long_name="LWdn at 200mb"    unit="W/m2" />
142        <field id="LWdn200clr"    long_name="LWdn clear sky at 200mb"    unit="W/m2" />
143        <field id="sols"    long_name="Solar rad. at surf."    unit="W/m2" />
144        <field id="sols0"    long_name="Solar rad. at surf."    unit="W/m2" />
145        <field id="soll"    long_name="IR rad. at surface"    unit="W/m2" />
146        <field id="soll0"    long_name="IR rad. at surface"    unit="W/m2" />
147        <field id="radsol"    long_name="Rayonnement au sol"    unit="W/m2" />
148        <field id="SWupSFC"    long_name="SWup at surface"    unit="W/m2" />
149        <field id="SWupSFCclr"    long_name="SWup clear sky at surface"    unit="W/m2" />
150        <field id="SWupSFCcleanclr"    long_name="SWup clean (no aerosol) clear sky at surface"    unit="W/m2" />
151        <field id="SWdnSFC"    long_name="SWdn at surface"    unit="W/m2" />
152        <field id="SWdnSFCclr"    long_name="SWdn clear sky at surface"    unit="W/m2" />
153        <field id="SWdnSFCcleanclr"    long_name="SWdn clean (no aerosol) clear sky at surface"    unit="W/m2" />
154        <field id="fdiffSWdnSFC"    long_name="Fraction of diffuse SWdn at surface"    unit="-" />
155        <field id="LWupSFC"    long_name="Upwd. IR rad. at surface"    unit="W/m2" />
156        <field id="LWupSFCclr"    long_name="CS Upwd. IR rad. at surface"    unit="W/m2" />
157        <field id="LWupTOAcleanclr"    long_name="CS clean (no aerosol) Upwd. IR rad. at TOA"    unit="W/m2" />
158        <field id="LWdnSFC"    long_name="Down. IR rad. at surface"    unit="W/m2" />
159        <field id="LWdnSFCclr"    long_name="Down. CS IR rad. at surface"    unit="W/m2" />
160        <field id="LWdnSFCcleanclr"    long_name="Down. CS clean (no aerosol) IR rad. at surface"    unit="W/m2" />
161        <field id="bils"    long_name="Surf. total heat flux"    unit="W/m2" />
162        <field id="bils_tke"    long_name="Surf. total heat flux"    unit="W/m2" />
163        <field id="bils_diss"    long_name="Surf. total heat flux"    unit="W/m2" />
164        <field id="bils_ec"    long_name="Surf. total heat flux"    unit="W/m2" />
165        <field id="bils_kinetic"    long_name="Surf. total heat flux"    unit="W/m2" />
166        <field id="bils_enthalp"    long_name="Surf. total heat flux"    unit="W/m2" />
167        <field id="bils_latent"    long_name="Surf. total heat flux"    unit="W/m2" />
168        <field id="bils_ech"    long_name="peu importe"    unit="W/m2" />
169        <field id="ustr_gwd_hines"    long_name="zonal wind stress Hines gravity waves"    unit="Pa" />
170        <field id="vstr_gwd_hines"    long_name="meridional wind stress Hines gravity waves"    unit="Pa" />
171        <field id="ustr_gwd_front"    long_name="zonal wind stress fronts gravity waves"    unit="Pa" />
172        <field id="vstr_gwd_front"    long_name="meridional wind stress fronts gravity waves"    unit="Pa" />
173        <field id="ustr_gwd_rando"    long_name="zonal wind stress random gravity waves"    unit="Pa" />
174        <field id="vstr_gwd_rando"    long_name="meridinal wind stress random gravity waves"    unit="Pa" />
175        <field id="sens"    long_name="Sensible heat flux"    unit="W/m2" />
176        <field id="sens_x"    long_name="sens off-wake"    unit="W/m2" />
177        <field id="sens_w"    long_name="sens within-wake"    unit="W/m2" />
178        <field id="flat_x"    long_name="flat off-wake"    unit="W/m2" />
179        <field id="flat_w"    long_name="flat within-wake"    unit="W/m2" />
180        <field id="delta_tsurf"    long_name="Temperature difference (w-x)"    unit="K" enabled="false" /> <!-- ym --field disabled-- delta_tsurf is not conform to the associated grid (the is an arry containing all sub_surface) --> 
181        <field id="cdragh_x"    long_name="cdragh off-wake"    unit="-" />
182        <field id="cdragh_w"    long_name="cdragh within-wake"    unit="-" />
183        <field id="cdragm_x"    long_name="cdragm off-wake"    unit="-" />
184        <field id="cdragm_w"    long_name="cdragm within-wake"    unit="-" />
185        <field id="kh"    long_name="Kh"    unit="kg/s/m2" />
186        <field id="kh_x"    long_name="cdragm off-wake"    unit="kg/s/m2" />
187        <field id="kh_w"    long_name="cdragm within-wake"    unit="kg/s/m2" />
188        <field id="fder"    long_name="Heat flux derivation"    unit="W/m2" />
189        <field id="ffonte"    long_name="Thermal flux for snow melting"    unit="W/m2" />
190        <field id="fqcalving"    long_name="Ice Calving"    unit="kg/m2/s" />
191        <field id="fqfonte"    long_name="Land ice melt"    unit="kg/m2/s" />
192        <field id="runofflic"  long_name="Land ice melt to ocean" unit="kg/m2/s" />
193        <field id="mrroli"  long_name="Runoff flux over land ice" unit="kg/m2/s" />
194        <field id="taux"    long_name="Zonal wind stress"    unit="Pa" />
195        <field id="tauy"    long_name="Meridional wind stress"    unit="Pa" />
196        <field id="taux_ter"    long_name="Zonal wind stress ter"    unit="Pa" />
197        <field id="taux_lic"    long_name="Zonal wind stress lic"    unit="Pa" />
198        <field id="taux_oce"    long_name="Zonal wind stress oce"    unit="Pa" />
199        <field id="taux_sic"    long_name="Zonal wind stress sic"    unit="Pa" />
200        <field id="tauy_ter"    long_name="Meridional wind stress ter"    unit="Pa" />
201        <field id="tauy_lic"    long_name="Meridional wind stress lic"    unit="Pa" />
202        <field id="tauy_oce"    long_name="Meridional wind stress oce"    unit="Pa" />
203        <field id="tauy_sic"    long_name="Meridional wind stress sic"    unit="Pa" />
204        <field id="pourc_ter"    long_name="% ter"    unit="%" />
205        <field id="pourc_lic"    long_name="% lic"    unit="%" />
206        <field id="pourc_oce"    long_name="% oce"    unit="%" />
207        <field id="pourc_sic"    long_name="% sic"    unit="%" />
208        <field id="fract_ter"    long_name="Fraction ter"    unit="1" />
209        <field id="fract_lic"    long_name="Fraction lic"    unit="1" />
210        <field id="fract_oce"    long_name="Fraction oce"    unit="1" />
211        <field id="fract_sic"    long_name="Fraction sic"    unit="1" />
212        <field id="tsol_ter"    long_name="Temperature ter"    unit="K" />
213        <field id="tsol_lic"    long_name="Temperature lic"    unit="K" />
214        <field id="tsol_oce"    long_name="Temperature oce"    unit="K" />
215        <field id="tsol_sic"    long_name="Temperature sic"    unit="K" />
216        <field id="evappot_ter"    long_name="Potential evaporation ter"    unit="kg/(m2*s)" />
217        <field id="evappot_lic"    long_name="Potential evaporation lic"    unit="kg/(m2*s)" />
218        <field id="evappot_oce"    long_name="Potential evaporation oce"    unit="kg/(m2*s)" />
219        <field id="evappot_sic"    long_name="Potential evaporation sic"    unit="kg/(m2*s)" />
220        <field id="sens_ter"    long_name="Sensible heat flux ter"    unit="W/m2" />
221        <field id="sens_lic"    long_name="Sensible heat flux lic"    unit="W/m2" />
222        <field id="sens_oce"    long_name="Sensible heat flux oce"    unit="W/m2" />
223        <field id="sens_sic"    long_name="Sensible heat flux sic"    unit="W/m2" />
224        <field id="lat_ter"    long_name="Latent heat flux ter"    unit="W/m2" />
225        <field id="lat_lic"    long_name="Latent heat flux lic"    unit="W/m2" />
226        <field id="lat_oce"    long_name="Latent heat flux oce"    unit="W/m2" />
227        <field id="lat_sic"    long_name="Latent heat flux sic"    unit="W/m2" />
228        <field id="flw_ter"    long_name="LW ter"    unit="W/m2" />
229        <field id="flw_lic"    long_name="LW lic"    unit="W/m2" />
230        <field id="flw_oce"    long_name="LW oce"    unit="W/m2" />
231        <field id="flw_sic"    long_name="LW sic"    unit="W/m2" />
232        <field id="fsw_ter"    long_name="SW ter"    unit="W/m2" />
233        <field id="fsw_lic"    long_name="SW lic"    unit="W/m2" />
234        <field id="fsw_oce"    long_name="SW oce"    unit="W/m2" />
235        <field id="fsw_sic"    long_name="SW sic"    unit="W/m2" />
236        <field id="wbils_ter"    long_name="Bilan sol ter"    unit="W/m2" />
237        <field id="wbils_lic"    long_name="Bilan sol lic"    unit="W/m2" />
238        <field id="wbils_oce"    long_name="Bilan sol oce"    unit="W/m2" />
239        <field id="wbils_sic"    long_name="Bilan sol sic"    unit="W/m2" />
240        <field id="wbilo_ter"    long_name="Bilan eau ter"    unit="kg/(m2*s)" />
241        <field id="wbilo_lic"    long_name="Bilan eau lic"    unit="kg/(m2*s)" />
242        <field id="wbilo_oce"    long_name="Bilan eau oce"    unit="kg/(m2*s)" />
243        <field id="wbilo_sic"    long_name="Bilan eau sic"    unit="kg/(m2*s)" />
244        <field id="wevap_ter"    long_name="Evap eau ter"    unit="kg/(m2*s)" />
245        <field id="wevap_lic"    long_name="Evap eau lic"    unit="kg/(m2*s)" />
246        <field id="wevap_oce"    long_name="Evap eau oce"    unit="kg/(m2*s)" />
247        <field id="wevap_sic"    long_name="Evap eau sic"    unit="kg/(m2*s)" />
248        <field id="wrain_ter"    long_name="Pluie eau ter"    unit="kg/(m2*s)" />
249        <field id="wrain_lic"    long_name="Pluie eau lic"    unit="kg/(m2*s)" />
250        <field id="wrain_oce"    long_name="Pluie eau oce"    unit="kg/(m2*s)" />
251        <field id="wrain_sic"    long_name="Pluie eau sic"    unit="kg/(m2*s)" />
252        <field id="wsnow_ter"    long_name="Neige eau ter"    unit="kg/(m2*s)" />
253        <field id="wsnow_lic"    long_name="Neige eau lic"    unit="kg/(m2*s)" />
254        <field id="wsnow_oce"    long_name="Neige eau oce"    unit="kg/(m2*s)" />
255        <field id="wsnow_sic"    long_name="Neige eau sic"    unit="kg/(m2*s)" />
256        <field id="cdrm"    long_name="Momentum drag coef."    unit="-" />
257        <field id="cdrh"    long_name="Heat drag coef."    unit="-" />
258        <field id="cldl"    long_name="Low-level cloudiness"    unit="-" />
259        <field id="cldm"    long_name="Mid-level cloudiness"    unit="-" />
260        <field id="cldh"    long_name="High-level cloudiness"    unit="-" />
261        <field id="cldt"    long_name="Total cloudiness"    unit="-" />
262        <field id="cldq"    long_name="Cloud liquid water path"    unit="kg/m2" />
263        <field id="lwp"    long_name="Cloud water path"    unit="kg/m2" />
264        <field id="iwp"    long_name="Cloud ice water path"    unit="kg/m2" />
265        <field id="ue"    long_name="Zonal energy transport"    unit="-" />
266        <field id="ve"    long_name="Merid energy transport"    unit="-" />
267        <field id="uq"    long_name="Zonal humidity transport"    unit="-" />
268        <field id="vq"    long_name="Merid humidity transport"    unit="-" />
269        <field id="uwat"    long_name="Zonal total water transport"    unit="-" />
270        <field id="vwat"    long_name="Merid total water transport"    unit="-" />
271        <field id="cape"    long_name="Conv avlbl pot ener"    unit="J/kg" />
272        <field id="pbase"    long_name="Cld base pressure"    unit="Pa" />
273        <field id="ptop"    long_name="Cld top pressure"    unit="Pa" />
274        <field id="fbase"    long_name="Cld base mass flux"    unit="kg/m2/s" />
275        <field id="plcl"    long_name="Lifting Condensation Level"    unit="hPa" enabled=".false." />
276        <field id="plfc"    long_name="Level of Free Convection"    unit="hPa" />
277        <field id="wbeff"    long_name="Conv. updraft velocity at LFC (inf100)"    unit="m/s" />
278        <field id="convoccur"    long_name="Convective occurence"    unit="-" />
279        <field id="prw"    long_name="Precipitable water"    unit="kg/m2" />
280        <field id="prlw"   long_name="Precipitable liquid water"  unit="kg/m2" />
281        <field id="prsw"   long_name="Precipitable solid water"  unit="kg/m2" />
282        <field id="prbsw"   long_name="Precipitable blowing snow"  unit="kg/m2" />
283        <field id="s_pblh"    long_name="Boundary Layer Height"    unit="m" />
284        <field id="s_pblt"    long_name="t at Boundary Layer Height"    unit="K" />
285        <field id="s_lcl"    long_name="Condensation level"    unit="m" />
286        <field id="s_therm"    long_name="Exces du thermique"    unit="K" />
287        <field id="slab_bils_oce"    long_name="Bilan au sol sur ocean slab"    unit="W/m2" />
288        <field id="ale_bl"    long_name="ALE BL"    unit="m2/s2" />
289        <field id="alp_bl"    long_name="ALP BL"    unit="m2/s2" />
290        <field id="ale_wk"    long_name="ALE WK"    unit="m2/s2" />
291        <field id="alp_wk"    long_name="ALP WK"    unit="m2/s2" />
292        <field id="ale"    long_name="ALE"    unit="m2/s2" />
293        <field id="alp"    long_name="ALP"    unit="W/m2" />
294        <field id="cin"    long_name="Convective INhibition"    unit="m2/s2" />
295        <field id="wape"    long_name="-"    unit="-" />
296        <field id="n2"    long_name="Nombre de panaches de type 2"    unit="-" />
297        <field id="s2"    long_name="Surface moyenne des panaches de type 2"    unit="m2" />
298        <field id="proba_notrig"    long_name="Probabilite de non-declenchement"    unit="-" />
299        <field id="random_notrig"    long_name="Tirage aleatoire de non-declenchement"    unit="-" />
300        <field id="cv_gen"    long_name="Cumulonimbus genesis"    unit="1/(m2 s)" />
301        <field id="ale_bl_stat"    long_name="ALE_BL_STAT"    unit="m2/s2" />
302        <field id="ale_bl_trig"    long_name="ALE_BL_STAT + Condition P>Pseuil"    unit="m2/s2" />
303        <field id="alp_bl_det"    long_name="ALP_BL_DET"    unit="W/m2" />
304        <field id="alp_bl_fluct_m"    long_name="ALP_BL_FLUCT_M"    unit="W/m2" />
305        <field id="alp_bl_fluct_tke"    long_name="ALP_BL_FLUCT_TKE"    unit="W/m2" />
306        <field id="alp_bl_conv"    long_name="ALP_BL_CONV"    unit="W/m2" />
307        <field id="alp_bl_stat"    long_name="ALP_BL_STAT"    unit="W/m2" />
308        <field id="u850"    long_name="Zonal wind 850hPa"    unit="m/s" detect_missing_value=".true." />
309        <field id="u700"    long_name="Zonal wind 700hPa"    unit="m/s" detect_missing_value=".true." />
310        <field id="u500"    long_name="Zonal wind 500hPa"    unit="m/s" detect_missing_value=".true." />
311        <field id="u200"    long_name="Zonal wind 200hPa"    unit="m/s" detect_missing_value=".true." />
312        <field id="u100"    long_name="Zonal wind 100hPa"    unit="m/s" detect_missing_value=".true." />
313        <field id="u50"     long_name="Zonal wind 50hPa"    unit="m/s" detect_missing_value=".true." />
314        <field id="u10"     long_name="Zonal wind 10hPa"    unit="m/s" detect_missing_value=".true." />
315        <field id="v850"    long_name="Meridional wind 850hPa"    unit="m/s" detect_missing_value=".true." />
316        <field id="v700"    long_name="Meridional wind 700hPa"    unit="m/s" detect_missing_value=".true." />
317        <field id="v500"    long_name="Meridional wind 500hPa"    unit="m/s" detect_missing_value=".true." />
318        <field id="v200"    long_name="Meridional wind 200hPa"    unit="m/s" detect_missing_value=".true." />
319        <field id="v100"    long_name="Meridional wind 100hPa"    unit="m/s" detect_missing_value=".true." />
320        <field id="v50"     long_name="Meridional wind 50hPa"    unit="m/s" detect_missing_value=".true." />
321        <field id="v10"    long_name="Meridional wind 10hPa"    unit="m/s" detect_missing_value=".true." />
322        <field id="w850"    long_name="Vertical wind 850hPa"    unit="Pa/s" detect_missing_value=".true." />
323        <field id="w700"    long_name="Vertical wind 700hPa"    unit="Pa/s" detect_missing_value=".true." />
324        <field id="w500"    long_name="Vertical wind 500hPa"    unit="Pa/s" detect_missing_value=".true." />
325        <field id="w200"    long_name="Vertical wind 200hPa"    unit="Pa/s" detect_missing_value=".true." />
326        <field id="w100"    long_name="Vertical wind 100hPa"    unit="Pa/s" detect_missing_value=".true." />
327        <field id="w50"    long_name="Vertical wind 50hPa"    unit="Pa/s" detect_missing_value=".true." />
328        <field id="w10"    long_name="Vertical wind 10hPa"    unit="Pa/s" detect_missing_value=".true." />
329        <field id="t850"    long_name="Temperature 850hPa"    unit="K" detect_missing_value=".true." />
330        <field id="t700"    long_name="Temperature 700hPa"    unit="K" detect_missing_value=".true." />
331        <field id="t500"    long_name="Temperature 500hPa"    unit="K" detect_missing_value=".true." />
332        <field id="t200"    long_name="Temperature 200hPa"    unit="K" detect_missing_value=".true." />
333        <field id="t100"    long_name="Temperature 100hPa"    unit="K" detect_missing_value=".true." />
334        <field id="t50"    long_name="Temperature 50hPa"    unit="K" detect_missing_value=".true." />
335        <field id="t10"    long_name="Temperature 10hPa"    unit="K" detect_missing_value=".true." />
336        <field id="q850"    long_name="Specific humidity 850hPa"    unit="kg/kg" detect_missing_value=".true." />
337        <field id="q700"    long_name="Specific humidity 700hPa"    unit="kg/kg" detect_missing_value=".true." />
338        <field id="q500"    long_name="Specific humidity 500hPa"    unit="kg/kg" detect_missing_value=".true." />
339        <field id="q200"    long_name="Specific humidity 200hPa"    unit="kg/kg" detect_missing_value=".true." />
340        <field id="q100"    long_name="Specific humidity 100hPa"    unit="kg/kg" detect_missing_value=".true." />
341        <field id="q50"    long_name="Specific humidity 50hPa"    unit="kg/kg" detect_missing_value=".true." />
342        <field id="q10"    long_name="Specific humidity 10hPa"    unit="kg/kg" detect_missing_value=".true." />
343        <field id="z850"    long_name="Geopotential height 850hPa"    unit="m" detect_missing_value=".true." />
344        <field id="z700"    long_name="Geopotential height 700hPa"    unit="m" detect_missing_value=".true." />
345        <field id="z500"    long_name="Geopotential height 500hPa"    unit="m" detect_missing_value=".true." />
346        <field id="z200"    long_name="Geopotential height 200hPa"    unit="m" detect_missing_value=".true." />
347        <field id="z100"    long_name="Geopotential height 100hPa"    unit="m" detect_missing_value=".true." />
348        <field id="z50"    long_name="Geopotential height 50hPa"    unit="m" detect_missing_value=".true." />
349        <field id="z10"    long_name="Geopotential height 10hPa"    unit="m" detect_missing_value=".true." />
350        <field id="t_oce_sic"    long_name="Temp mixte oce-sic"    unit="K" />
351        <field id="weakinv"    long_name="Weak inversion"    unit="-" />
352        <field id="dthmin"    long_name="dTheta mini"    unit="K/m" />
353        <field id="u10_ter"    long_name="-"    unit="-" />
354        <field id="u10_lic"    long_name="-"    unit="-" />
355        <field id="u10_oce"    long_name="-"    unit="-" />
356        <field id="u10_sic"    long_name="-"    unit="-" />
357        <field id="v10_ter"    long_name="-"    unit="-" />
358        <field id="v10_lic"    long_name="-"    unit="-" />
359        <field id="v10_oce"    long_name="-"    unit="-" />
360        <field id="v10_sic"    long_name="-"    unit="-" />
361        <field id="rh2m"    long_name="Relative humidity at 2m"    unit="%" />
362        <field id="rh2m_max"    field_ref="rh2m" operation="maximum" enabled="false"/> <!-- ym Problem : field is disabled check rh2m_min has a reference (field_ref) to rh2 but is also sent by model which is not compatible-->
363        <field id="rh2m_min"    field_ref="rh2m" operation="minimum" enabled="false"/> <!-- ym Problem : field is disabled check rh2m_max has a reference (field_ref) to rh2 but is also sent by model which is not compatible-->
364<!--        <field id="rh2m_min"    long_name="Min Relative humidity at 2m"    unit="%" /> -->
365<!--        <field id="rh2m_max"    long_name="Max Relative humidity at 2m"    unit="%" /> -->
366        <field id="qsat2m"    long_name="Saturant humidity at 2m"    unit="%" />
367        <field id="tpot"    long_name="Surface air potential temperature"    unit="K" />
368        <field id="tpote"    long_name="Surface air equivalent potential temperature"    unit="K" />
369        <field id="SWnetOR"    long_name="Sfce net SW radiation OR"    unit="W/m2" />
370        <field id="SWdownOR"    long_name="Sfce incident SW radiation OR"    unit="W/m2" />
371        <field id="LWdownOR"    long_name="Sfce incident LW radiation OR"    unit="W/m2" />
372        <field id="snowl"    long_name="Solid Large-scale Precip."    unit="kg/(m2*s)" />
373        <field id="cape_max"    long_name="CAPE max."    unit="J/kg" operation="maximum"/>
374        <field id="solldown"    long_name="Down. IR rad. at surface"    unit="W/m2" />
375        <field id="dtsvdfo"    long_name="Boundary-layer dTs(o)"    unit="K/s" />
376        <field id="dtsvdft"    long_name="Boundary-layer dTs(t)"    unit="K/s" />
377        <field id="dtsvdfg"    long_name="Boundary-layer dTs(g)"    unit="K/s" />
378        <field id="dtsvdfi"    long_name="Boundary-layer dTs(g)"    unit="K/s" />
379        <field id="rugs"    long_name="rugosity"    unit="-" />
380        <field id="z0m"    long_name="roughness length, momentum"    unit="-" />
381        <field id="z0h"    long_name="roughness length, enthalpy"    unit="-" />
382        <field id="topswad"    long_name="ADE at TOA"    unit="W/m2" />
383        <field id="topswad0"    long_name="ADE clear-sky at TOA"    unit="W/m2" />
384        <field id="topswai"    long_name="AIE at TOA"    unit="W/m2" />
385        <field id="solswad"    long_name="ADE at SRF"    unit="W/m2" />
386        <field id="solswad0"    long_name="ADE clear-sky at SRF"    unit="W/m2" />
387        <field id="solswai"    long_name="AIE at SFR"    unit="W/m2" />
388        <field id="toplwad"    long_name="LW-ADE at TOA" unit="W/m2" />
389        <field id="toplwad0"    long_name="LW-ADE clear-sky at TOA"    unit="W/m2" />
390        <field id="toplwai"    long_name="LW-AIE clear-sky at TOA"    unit="W/m2" />
391        <field id="sollwad"    long_name="LW-ADE at SRF" unit="W/m2" />
392        <field id="sollwad0"    long_name="LW-ADE clear-sky at SRF"    unit="W/m2" />
393        <field id="sollwai"    long_name="LW-AIE at SRF" unit="W/m2" />
394        <field id="od550_ASBCM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
395        <field id="od550_ASPOMM"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
396        <field id="od550_ASSO4M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
397        <field id="od550_CSSO4M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
398        <field id="od550_SSSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
399        <field id="od550_ASSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
400        <field id="od550_CSSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
401        <field id="od550_CIDUSTM"  long_name="Aerosol Optical depth at 550 nm "    unit="1" />
402        <field id="od550_AIBCM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
403        <field id="od550_AIPOMM"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
404        <field id="od550_ASNO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
405        <field id="od550_CSNO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
406        <field id="od550_CINO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
407        <field id="od550_STRAT"    long_name="Aerosol Optical depth at 550 nm "    unit="1"  />
408        <field id="dryod550_ASBCM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
409        <field id="dryod550_ASPOMM"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
410        <field id="dryod550_ASSO4M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
411        <field id="dryod550_CSSO4M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
412        <field id="dryod550_SSSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
413        <field id="dryod550_ASSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
414        <field id="dryod550_CSSSM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
415        <field id="dryod550_CIDUSTM"  long_name="Aerosol Optical depth at 550 nm "    unit="1" />
416        <field id="dryod550_AIBCM"    long_name="Aerosol Optical depth at 550 nm "    unit="1" />
417        <field id="dryod550_AIPOMM"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
418        <field id="dryod550_ASNO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
419        <field id="dryod550_CSNO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
420        <field id="dryod550_CINO3M"   long_name="Aerosol Optical depth at 550 nm "    unit="1" />
421        <field id="od_10um_STRAT"  long_name="Stratospheric Aerosol Optical depth at 10 um" unit="-" />
422        <field id="od443aer"    long_name="Total aerosol optical depth at 440nm" unit="-" />
423        <field id="od550aer"    long_name="Total aerosol optical depth at 550nm" unit="-" />
424        <field id="dryod550aer" long_name="Total dry aerosol optical depth at 550nm"    unit="-" />
425        <field id="od865aer"    long_name="Total aerosol optical depth at 870nm"    unit="-" />
426        <field id="abs550aer"   long_name="Absorption aerosol optical depth at 550nm"    unit="-" />
427        <field id="od550lt1aer" long_name="Fine mode optical depth"    unit="-" />
428        <field id="sconcso4"    long_name="Surface Concentration of Sulfate "    unit="kg/m3" />
429        <field id="sconcno3"    long_name="Surface Concentration of Nitrate "    unit="kg/m3" />
430        <field id="sconcoa"     long_name="Surface Concentration of Organic Aerosol "    unit="kg/m3" />
431        <field id="sconcbc"     long_name="Surface Concentration of Black Carbon "    unit="kg/m3" />
432        <field id="sconcss"     long_name="Surface Concentration of Sea Salt "    unit="kg/m3" />
433        <field id="sconcdust"   long_name="Surface Concentration of Dust "    unit="kg/m3" />
434        <field id="loadso4"   long_name="Column Load of Sulfate "    unit="kg/m2" />
435        <field id="loadoa"    long_name="Column Load of Organic Aerosol "    unit="kg/m2" />
436        <field id="loadbc"    long_name="Column Load of Black Carbon "    unit="kg/m2" />
437        <field id="loadss"    long_name="Column Load of Sea Salt "    unit="kg/m2" />
438        <field id="loaddust"  long_name="Column Load of Dust "    unit="kg/m2" />
439        <field id="loadno3"   long_name="Column Load of Nitrate " unit="kg/m2" />
440        <field id="swtoaas_nat"    long_name="Natural aerosol radiative forcing all-sky at TOA"    unit="W/m2" />
441        <field id="swsrfas_nat"    long_name="Natural aerosol radiative forcing all-sky at SRF"    unit="W/m2" />
442        <field id="swtoacs_nat"    long_name="Natural aerosol radiative forcing clear-sky at TOA"    unit="W/m2" />
443        <field id="swsrfcs_nat"    long_name="Natural aerosol radiative forcing clear-sky at SRF"    unit="W/m2" />
444        <field id="swtoaas_ant"    long_name="Anthropogenic aerosol radiative forcing all-sky at TOA"    unit="W/m2" />
445        <field id="swsrfas_ant"    long_name="Anthropogenic aerosol radiative forcing all-sky at SRF"    unit="W/m2" />
446        <field id="swtoacs_ant"    long_name="Anthropogenic aerosol radiative forcing clear-sky at TOA"    unit="W/m2" />
447        <field id="swsrfcs_ant"    long_name="Anthropogenic aerosol radiative forcing clear-sky at SRF"    unit="W/m2" />
448        <field id="swtoacf_nat"    long_name="Natural aerosol impact on cloud radiative forcing at TOA"    unit="W/m2" />
449        <field id="swsrfcf_nat"    long_name="Natural aerosol impact on cloud radiative forcing  at SRF"    unit="W/m2" />
450        <field id="swtoacf_ant"    long_name="Anthropogenic aerosol impact on cloud radiative forcing at TOA"    unit="W/m2" />
451        <field id="swsrfcf_ant"    long_name="Anthropogenic aerosol impact on cloud radiative forcing at SRF"    unit="W/m2" />
452        <field id="swtoacf_zero"    long_name="Cloud radiative forcing (allsky-clearsky fluxes) at TOA"    unit="W/m2" />
453        <field id="swsrfcf_zero"    long_name="Cloud radiative forcing (allsky-clearsky fluxes) at SRF"    unit="W/m2" />
454        <field id="cldncl"    long_name="CDNC at top of liquid water cloud"    unit="m-3" />
455        <field id="reffclwtop"    long_name="Droplet effective radius at top of liquid water cloud"    unit="m" />
456        <field id="cldnvi"    long_name="Column Integrated Cloud Droplet Number"    unit="m-2" />
457        <field id="lcc"    long_name="Cloud liquid fraction at top of cloud"    unit="1" />
458        <field id="lcc_limit"          field_ref="lcc" > lcc /= 0 ? lcc : 1e-15  </field>
459        <field id="wvapp"    long_name="-"    unit="-" />
460        <field id="albe_ter"    long_name="Albedo VIS surf. ter"    unit="-" />
461        <field id="albe_lic"    long_name="Albedo VIS surf. lic"    unit="-" />
462        <field id="albe_oce"    long_name="Albedo VIS surf. oce"    unit="-" />
463        <field id="albe_sic"    long_name="Albedo VIS surf. sic"    unit="-" />
464        <field id="ages_ter"    long_name="Snow age ter"    unit="day" />
465        <field id="ages_lic"    long_name="Snow age lic"    unit="day" />
466        <field id="ages_oce"    long_name="Snow age oce"    unit="day" />
467        <field id="ages_sic"    long_name="Snow age sic"    unit="day" />
468        <field id="snow_ter"    long_name="Snow"    unit="kg/m2" />
469        <field id="snow_lic"    long_name="Snow"    unit="kg/m2" />
470        <field id="snow_oce"    long_name="Snow"    unit="kg/m2" />
471        <field id="snow_sic"    long_name="Snow"    unit="kg/m2" />
472        <field id="rugs_ter"    long_name="Surface roughness ter"    unit="m" />
473        <field id="rugs_lic"    long_name="Surface roughness lic"    unit="m" />
474        <field id="rugs_oce"    long_name="Surface roughness oce"    unit="m" />
475        <field id="rugs_sic"    long_name="Surface roughness sic"    unit="m" />
476        <field id="z0m_ter"    long_name="roughness length, momentum ter"    unit="m" />
477        <field id="z0m_lic"    long_name="roughness length, momentum lic"    unit="m" />
478        <field id="z0m_oce"    long_name="roughness length, momentum oce"    unit="m" />
479        <field id="z0m_sic"    long_name="roughness length, momentum sic"    unit="m" />
480        <field id="z0h_ter"    long_name="roughness length, enthalpy ter"    unit="m" />
481        <field id="z0h_lic"    long_name="roughness length, enthalpy lic"    unit="m" />
482        <field id="z0h_oce"    long_name="roughness length, enthalpy oce"    unit="m" />
483        <field id="z0h_sic"    long_name="roughness length, enthalpy sic"    unit="m" />
484        <field id="sens_rain_oce"  long_name="Sensible heat flux associated withliquid prec. over ocean"    unit="W/m2" />
485        <field id="sens_rain_sic"  long_name="Sensible heat flux associated with liquid prec. over seaice"    unit="W/m2" />
486        <field id="sens_snow_oce"  long_name="Sensible heat flux associated with solid prec. over ocean"    unit="W/m2" />
487        <field id="sens_snow_sic"  long_name="Sensible heat flux associated with solid prec. over seaice"    unit="W/m2" />
488        <field id="lat_rain_oce"  long_name="Latent heat flux associated with liquid prec. over ocean"    unit="W/m2" />
489        <field id="lat_rain_sic"  long_name="Latent heat flux associated with liquid prec. over seaice"    unit="W/m2" />
490        <field id="lat_snow_oce"  long_name="Latent heat flux associated with solid prec. over ocean"    unit="W/m2" />
491        <field id="lat_snow_sic"  long_name="Latent heat flux associated with solid prec. over seaice"    unit="W/m2" />
492        <field id="alb1"    long_name="Surface VIS albedo"    unit="-" />
493        <field id="alb2"    long_name="Surface Near IR albedo"    unit="-" />
494        <field id="ftime_con"    long_name="Fraction of time convection Occurs"    unit="-" operation="instant" />
495        <field id="ftime_deepcv"    long_name="Fraction of time deep convection Occurs"    unit="-" />
496        <field id="wake_h"    long_name="wake height"    unit="m" />
497        <field id="wake_dens"    long_name="number of wakes per m2"    unit="1/m2" />
498        <field id="wake_s"    long_name="wake_s"    unit="-" />
499        <field id="epmax"    long_name="epmax en fn cape"    unit="su" />
500        <field id="plulth"    long_name="Rainfall therm."    unit="K/s" />
501        <field id="plulst"    long_name="Rainfall strat."    unit="K/s" />
502        <field id="lmaxth"    long_name="Upper level thermals"    unit="-" />
503        <field id="ftime_th"    long_name="Fraction of time Shallow convection occurs"    unit="-" />
504        <field id="f0_th"    long_name="Thermal closure mass flux"    unit="K/s" />
505        <field id="zmax_th"    long_name="Thermal plume height"    unit="K/s" />
506        <field id="rsut4co2"    long_name="TOA Out SW in 4xCO2 atmosphere"    unit="W/m2" />
507        <field id="rlut4co2"    long_name="TOA Out LW in 4xCO2 atmosphere"    unit="W/m2" />
508        <field id="rsutcs4co2"    long_name="TOA Out CS SW in 4xCO2 atmosphere"    unit="W/m2" />
509        <field id="rlutcs4co2"    long_name="TOA Out CS LW in 4xCO2 atmosphere"    unit="W/m2" />
510        <field id="dqphy2d"    long_name="Physics dQ"    unit="(kg/m2)/s" />
511        <field id="dqlphy2d"    long_name="Physics dQL"    unit="(kg/m2)/s" />
512        <field id="dqsphy2d"    long_name="Physics dQS"    unit="(kg/m2)/s" />
513        <field id="dqbsphy2d"    long_name="Physics dQBS"    unit="(kg/m2)/s" />
514        <field id="dqdyn2d"    long_name="Dynamics dQ"    unit="(kg/m2)/s" />
515        <field id="dqldyn2d"   long_name="Dynamics dQL"    unit="(kg/m2)/s" />
516        <field id="dqsdyn2d"   long_name="Dynamics dQS"    unit="(kg/m2)/s" />
517        <field id="dqbsdyn2d"   long_name="Dynamics dQBS"    unit="(kg/m2)/s" />
518        <field id="dqcon2d"    long_name="Convection dQ"    unit="(kg/m2)/s" />
519        <field id="dqwak2d"    long_name="Wake dQ"    unit="(kg/m2)/s" />
520        <field id="dqlsc2d"    long_name="Condensation dQ"    unit="(kg/m2)/s" />
521        <field id="dqvdf2d"    long_name="Boundary-layer dQ"    unit="(kg/m2)/s" />
522        <field id="dqeva2d"    long_name="Reevaporation dQ"    unit="(kg/m2)/s" />
523        <field id="dqlscth2d"    long_name="dQ therm."    unit="(kg/m2)/s" />
524        <field id="dqlscst2d"    long_name="dQ strat."    unit="(kg/m2)/s" />
525        <field id="dqthe2d"    long_name="Thermal dQ"    unit="(kg/m2)/s" />
526        <field id="dqajs2d"    long_name="Dry ajdust dQ"    unit="(kg/m2)/s" />
527        <field id="tatp"    long_name="Dry ajdust dQ"    unit="(kg/m2)/s" />
528        <field id="p_tropopause"  long_name="Tropopause pressure" unit="Pa"   detect_missing_value=".true."  />
529        <field id="z_tropopause"  long_name="Tropopause height" unit="m"      detect_missing_value=".true."  />
530        <field id="t_tropopause"  long_name="Tropopause temperature" unit="K" detect_missing_value=".true."  />
531        <field id="colO3_strat"    long_name="Ozone stratospheric column"     unit="DU" />             <!-- Added ThL -->
532        <field id="colO3_trop"     long_name="Ozone tropospheric column"      unit="DU" />             <!-- Added ThL -->
533        <field id="flx_co2_land"   long_name="CO2 flux from land"             unit="kg CO2/m2/s" />    <!-- Added OB -->
534        <field id="flx_co2_ocean"  long_name="CO2 flux from ocean"            unit="kg CO2/m2/s" />    <!-- Added OB -->
535        <field id="flx_co2_ocean_cor"  long_name="correction of the CO2 flux from ocean"          unit="kg CO2/m2/s" />    <!-- Added PC -->
536        <field id="flx_co2_land_cor"   long_name="correction of the CO2 flux from land"           unit="kg CO2/m2/s" />    <!-- Added PC -->
537        <field id="flx_co2_ff"     long_name="CO2 flux from ff"               unit="kg CO2/m2/s" />    <!-- Added OB -->
538        <field id="flx_co2_bb"     long_name="CO2 flux from bb"               unit="kg CO2/m2/s" />    <!-- Added OB -->
539        <field id="delta_SST" long_name="ocean-air interface temperature minus bulk SST" unit="K" detect_missing_value=".true." />
540        <field id="delta_sal"
541               long_name="ocean-air interface salinity minus bulk salinity"
542               unit="ppt" detect_missing_value=".true." />
543        <field id="dS_ns" long_name="delta salinity near surface" unit="ppt" detect_missing_value=".true." />
544        <field id="dT_ns" long_name="sub-skin temperature minus foundation temperature" unit="K" detect_missing_value=".true." />
545        <field id="dTer"               long_name="interface temperature minus sub-skin temperature"            unit="K" detect_missing_value=".true." />
546        <field id="dSer"
547               long_name="salinity variation in the diffusive microlayer"
548               unit="ppt" detect_missing_value=".true." />
549        <field id="tkt" long_name="thickness of thermal microlayer"            unit="m"                detect_missing_value=".true." />
550        <field id="tks" long_name="thickness of salinity microlayer"           unit="m"                detect_missing_value=".true." />
551        <field id="taur" long_name="momentum flux due to rain"         unit="Pa"               detect_missing_value=".true." />
552        <field id="SSS" long_name="bulk sea-surface salinity" unit="ppt" detect_missing_value=".true." />
553    </field_group>
554
555    <field_group id="fields_3D" grid_ref="grid_glo_presnivs" >
556        <field id="tke"    long_name="TKE"    unit="m2/s2" />
557        <field id="tke_dissip" long_name="TKE DISSIPATION" unit="m2/s3" />
558        <field id="tke_ter"    long_name="Max Turb. Kinetic Energy ter"    unit="m2/s2" />
559        <field id="tke_lic"    long_name="Max Turb. Kinetic Energy lic"    unit="m2/s2" />
560        <field id="tke_oce"    long_name="Max Turb. Kinetic Energy oce"    unit="m2/s2" />
561        <field id="tke_sic"    long_name="Max Turb. Kinetic Energy sic"    unit="m2/s2" />
562        <field id="tke_max_ter"    long_name="Max Turb. Kinetic Energy ter"    unit="m2/s2" operation="maximum"/>
563        <field id="tke_max_lic"    long_name="Max Turb. Kinetic Energy lic"    unit="m2/s2" operation="maximum"/>
564        <field id="tke_max_oce"    long_name="Max Turb. Kinetic Energy oce"    unit="m2/s2" operation="maximum"/>
565        <field id="tke_max_sic"    long_name="Max Turb. Kinetic Energy sic"    unit="m2/s2" operation="maximum"/>
566        <field id="l_mix_ter"    long_name="PBL mixing length ter"    unit="m" />
567        <field id="l_mix_lic"    long_name="PBL mixing length lic"    unit="m" />
568        <field id="l_mix_oce"    long_name="PBL mixing length oce"    unit="m" />
569        <field id="l_mix_sic"    long_name="PBL mixing length sic"    unit="m" />
570        <field id="treedrg_ter"    long_name="tree drag profile ter "    unit="-" />
571        <field id="treedrg_lic"    long_name="tree drag profile ter "    unit="-" />
572        <field id="treedrg_oce"    long_name="tree drag profile ter "    unit="-" />
573        <field id="treedrg_sic"    long_name="tree drag profile ter "    unit="-" />
574        <field id="l_mixmin_ter"    long_name="min PBL mixing length ter"    unit="m" />
575        <field id="l_mixmin_lic"    long_name="min PBL mixing length lic"    unit="m" />
576        <field id="l_mixmin_oce"    long_name="min PBL mixing length oce"    unit="m" />
577        <field id="l_mixmin_sic"    long_name="min PBL mixing length sic"    unit="m" />
578        <field id="dltpbltke_ter"    long_name="TKE difference (w - x)"    unit="m2/s2" />
579        <field id="dltpbltke_lic"    long_name="TKE difference (w - x)"    unit="m2/s2" />
580        <field id="dltpbltke_oce"    long_name="TKE difference (w - x)"    unit="m2/s2" />
581        <field id="dltpbltke_sic"    long_name="TKE difference (w - x)"    unit="m2/s2" />
582        <field id="cldtau"    long_name="Cloud optical thickness"    unit="1" />
583        <field id="cldemi"    long_name="Cloud optical emissivity"    unit="1" />
584        <field id="tke_max"    long_name="TKE max"    unit="m2/s2" operation="maximum"/>
585        <field id="concso4"    long_name="Concentration of Sulfate "    unit="kg/m3" />
586        <field id="concno3"    long_name="Concentration of Nitrate "    unit="kg/m3" /> 
587        <field id="concoa"    long_name="Concentration of Organic Aerosol "    unit="kg/m3" />
588        <field id="concbc"    long_name="Concentration of Black Carbon "    unit="kg/m3" />
589        <field id="concss"    long_name="Concentration of Sea Salt "    unit="kg/m3" />
590        <field id="concdust"    long_name="Concentration of Dust "    unit="kg/m3" />
591        <field id="ec550aer"    long_name="Extinction at 550nm"    unit="m^-1" />
592        <field id="lwcon"    long_name="Cloud liquid water content seen by radiation"    unit="kg/kg" />
593        <field id="iwcon"    long_name="Cloud ice water content seen by radiation"    unit="kg/kg" />
594        <field id="temp"    long_name="Air temperature"    unit="K" />
595        <field id="theta"    long_name="Potential air temperature"    unit="K" />
596        <field id="ovap"    long_name="Specific humidity"    unit="kg/kg" />
597        <field id="ovapinit"    long_name="Specific humidity (begin of timestep)"    unit="kg/kg" />
598        <field id="oliq"    long_name="Liquid water"    unit="kg/kg" />
599        <field id="ocond"    long_name="Condensed water"    unit="kg/kg" />
600        <field id="qbs"    long_name="specific content of blowing snow"    unit="kg/kg" />
601        <field id="geop"    long_name="Geopotential height"    unit="m2/s2" />
602        <field id="geoph" field_ref="geop" long_name="Geopotential height" unit="m" > geop/9.80665 </field>
603        <field id="vitu"    long_name="Zonal wind"    unit="m/s" />
604        <field id="vitv"    long_name="Meridional wind"    unit="m/s" />
605        <field id="vitw"    long_name="Vertical wind"    unit="Pa/s" />
606        <field id="pres"    long_name="Air pressure"    unit="Pa" />
607        <field id="paprs"    long_name="Air pressure Inter-Couches"    unit="Pa" />
608        <field id="mass"    long_name="Masse Couches"    unit="kg/m2" />
609        <field id="zfull"    long_name="Altitude of full pressure levels"    unit="m" />
610        <field id="zhalf"    long_name="Altitude of half pressure levels"    unit="m" />
611        <field id="rneb"    long_name="Cloud fraction"    unit="-" />
612        <field id="rnebcon"    long_name="Convective Cloud Fraction"    unit="-" />
613        <field id="rnebls"    long_name="LS Cloud fraction"    unit="-" />
614        <field id="rneblsvol" long_name="LS Cloud fraction by volume"    unit="-" />
615        <field id="pfraclr" long_name="LS precip fraction clear-sky part"    unit="-" />               
616        <field id="pfracld" long_name="LS precip fraction cloudy part"    unit="-" />   
617        <field id="rhum"    long_name="Relative humidity"    unit="-" />
618        <field id="rhl" long_name="Relative humidity wrt liquid" unit="%" />
619        <field id="rhi" long_name="Relative humidity wrt ice" unit="%" />
620        <field id="ozone"    long_name="Ozone mole fraction"    unit="-" />
621        <field id="ozone_daylight"    long_name="Daylight ozone mole fraction"    unit="-" />
622        <field id="upwd"    long_name="saturated updraft"    unit="kg/m2/s" />
623        <field id="ep"    long_name="ep"    unit="su" />
624        <field id="duphy"    long_name="Physics du"    unit="K/s" />
625        <field id="dtphy"    long_name="Physics dT"    unit="K/s" />
626        <field id="dqphy"    long_name="Physics dQ"    unit="(kg/kg)/s" />
627        <field id="dqlphy"   long_name="Physics dQL"    unit="(kg/kg)/s" />
628        <field id="dqsphy"   long_name="Physics dQS"    unit="(kg/kg)/s" />
629        <field id="dqbsphy"   long_name="Physics dQBS"    unit="(kg/kg)/s" />
630        <field id="pr_con_l"    long_name="Convective precipitation lic"    unit="-" />
631        <field id="pr_con_i"    long_name="Convective precipitation ice"    unit="-" />
632        <field id="pr_lsc_l"    long_name="Large scale precipitation lic"    unit="-" />
633        <field id="pr_lsc_i"    long_name="Large scale precipitation ice"    unit="-" />
634        <field id="pr_bs"    long_name="precipitation blowing snow"    unit="-" />
635        <field id="re"    long_name="Cloud droplet effective radius"    unit="um" />
636        <field id="fl"    long_name="Denominator of Cloud droplet effective radius"    unit="-" />
637        <field id="scdnc"    long_name="Cloud droplet number concentration"    unit="m-3" />
638        <field id="reffclws"    long_name="Stratiform Cloud Droplet Effective Radius (aerosol diags.)"    unit="m" />
639        <field id="reffclwc"    long_name="Convective Cloud Droplet Effective Radius (aerosol diags.)"    unit="m" />
640        <field id="lcc3d"    long_name="Cloud liquid fraction"    unit="1" />
641        <field id="lcc3dcon"    long_name="Convective cloud liquid fraction"    unit="1" />
642        <field id="lcc3dstra"    long_name="Stratiform cloud liquid fraction"    unit="1" />
643        <field id="cldwatmxrat"    long_name="Cloud Water Mixing Ratio"    unit="1" />
644        <field id="icc3dcon"    long_name="Mass Fraction of Convective Cloud Ice"    unit="kg/kg" />
645        <field id="icc3dstra"    long_name="Mass Fraction of Stratiform Cloud Ice "    unit="kg/kg" />
646        <field id="cldicemxrat"    long_name="Cloud Ice Mixing Ratio"    unit="1" />
647        <field id="clwcon"    long_name="Convective Cloud Liquid water content"    unit="kg/kg" />
648        <field id="Mipsh"    long_name="mass flux shed from adiab. ascents"    unit="kg/m2/s" />
649        <field id="Ma"    long_name="undilute adiab updraft"    unit="kg/m2/s" />
650        <field id="dnwd"    long_name="saturated downdraft"    unit="kg/m2/s" />
651        <field id="dnwd0"    long_name="unsat. downdraft"    unit="kg/m2/s" />
652        <field id="mc"    long_name="Convective mass flux"    unit="kg/m2/s" />
653        <field id="dtdyn"    long_name="Dynamics dT"    unit="K/s" />
654        <field id="dqdyn"    long_name="Dynamics dQ"    unit="(kg/kg)/s" />
655        <field id="dqldyn"    long_name="Dynamics dQL"    unit="(kg/kg)/s" />
656        <field id="dqsdyn"    long_name="Dynamics dQS"    unit="(kg/kg)/s" />
657        <field id="dqbsdyn"    long_name="Dynamics dQBS"    unit="(kg/kg)/s" />       
658        <field id="dudyn"    long_name="Dynamics dU"    unit="m/s2" />
659        <field id="dvdyn"    long_name="Dynamics dV"    unit="m/s2" />
660        <field id="dtcon"    long_name="Convection dT"    unit="K/s" />
661        <field id="ducon"    long_name="Convection du"    unit="m/s2" />
662        <field id="dvcon"    long_name="Convection dv"    unit="m/s2" />
663        <field id="dqcon"    long_name="Convection dQ"    unit="(kg/kg)/s" />
664        <field id="dtwak"    long_name="Wake dT"    unit="K/s" />
665        <field id="dqwak"    long_name="Wake dQ"    unit="(kg/kg)/s" />
666        <field id="wake_deltat"    long_name="wake_deltat"    unit="-" />
667        <field id="wake_deltaq"    long_name="wake_deltaq"    unit="-" />
668        <field id="wake_omg"    long_name="wake_omg"    unit="-" />
669        <field id="wdtrainA"    long_name="precipitation from AA"    unit="-" />
670        <field id="wdtrainS"    long_name="precipitation from shedding of AA"    unit="-" />
671        <field id="wdtrainM"    long_name="precipitation from mixture"    unit="-" />
672        <field id="qtaa"    long_name="specific total water in adiabatic ascents"    unit="kg/kg" /> 
673        <field id="Clwaa"   long_name="specific condensed water in adiabatic ascents"    unit="kg/kg" />
674        <field id="ftd"    long_name="tend temp due aux descentes precip"    unit="-" />
675        <field id="fqd"    long_name="tend vap eau due aux descentes precip"    unit="-" />
676        <field id="dtlsc"    long_name="Condensation dT"    unit="K/s" />
677        <field id="dtlschr"    long_name="Large-scale condensational heating rate"    unit="K/s" />
678        <field id="dqlsc"    long_name="Condensation dQ"    unit="(kg/kg)/s" />
679        <field id="beta_prec"    long_name="LS Conversion rate to prec"    unit="(kg/kg)/s" />
680        <field id="dtvdf"    long_name="Boundary-layer dT"    unit="K/s" />
681        <field id="dtvdf_x"  long_name="dtvdf off_wake"    unit="K/s" />
682        <field id="dtvdf_w"  long_name="dtvdf within_wake"    unit="K/s" />
683        <field id="dtdis"    long_name="TKE dissipation dT"    unit="K/s" />
684        <field id="dqvdf"    long_name="Boundary-layer dQ"    unit="(kg/kg)/s" />
685        <field id="dqvdf_x" long_name="dqvdf off_wake" unit="(kg/kg)/s" />
686        <field id="dqvdf_w" long_name="dqvdf within_wake" unit="(kg/kg)/s" />
687        <field id="dteva"    long_name="Reevaporation dT"    unit="K/s" />
688        <field id="dqeva"    long_name="Reevaporation dQ"    unit="(kg/kg)/s" />
689        <field id="dqbsvdf"    long_name="Boundary-layer dQBS"    unit="(kg/kg)/s" />
690        <field id="dqbsbs"    long_name="Blowing snow dQBS"    unit="(kg/kg)/s" />
691        <field id="dqbs"    long_name="Blowing snow dQ"    unit="(kg/kg)/s" />
692        <field id="dtbs"    long_name="Blowing snow dT"    unit="(K)/s" />
693        <field id="dqlscth"    long_name="dQ therm."    unit="(kg/kg)/s" />
694        <field id="dqlscst"    long_name="dQ strat."    unit="(kg/kg)/s" />
695        <field id="dtlscth"    long_name="dQ therm."    unit="K/s" />
696        <field id="dtlscst"    long_name="dQ strat."    unit="K/s" />
697        <field id="ptconvth"    long_name="POINTS CONVECTIFS therm."    unit="-" />
698        <field id="ptconv"    long_name="POINTS CONVECTIFS"    unit="-" />
699        <field id="ratqs"    long_name="RATQS"    unit="-" />
700        <field id="dtthe"    long_name="Thermal dT"    unit="K/s" />
701        <field id="duthe"    long_name="Thermal du"    unit="m/s2" />
702        <field id="dvthe"    long_name="Thermal dv"    unit="m/s2" />
703        <field id="e_th"    long_name="Thermal plume entrainment"    unit="K/s" />
704        <field id="lambda_th"    long_name="Thermal plume vertical velocity"    unit="m/s" />
705        <field id="q_th"    long_name="Thermal plume total humidity"    unit="kg/kg" />
706        <field id="s_th"    long_name="Thermal plume saturation deficit"    unit="kg/kg" />
707        <field id="s_env"    long_name="Environment saturation deficit"    unit="kg/kg" />
708        <field id="sigma_th"    long_name="Thermal plume gauss variance"    unit="kg/kg" />
709        <field id="sigma_env"    long_name="Environment gauss variance"    unit="kg/kg" />
710        <field id="d_th"    long_name="Thermal plume detrainment"    unit="K/s" />
711        <field id="dqthe"    long_name="Thermal dQ"    unit="(kg/kg)/s" />
712        <field id="dtajs"    long_name="Dry adjust. dT"    unit="K/s" />
713        <field id="dqajs"    long_name="Dry adjust. dQ"    unit="(kg/kg)/s" />
714        <field id="dtswr"    long_name="SW radiation dT"    unit="K/s" />
715        <field id="dtsw0"    long_name="CS SW radiation dT"    unit="K/s" />
716        <field id="dtlwr"    long_name="LW radiation dT"    unit="K/s" />
717        <field id="dtlw0"    long_name="CS LW radiation dT"    unit="K/s" />
718        <field id="dtec"    long_name="Cinetic dissip dT"    unit="K/s" />
719        <field id="duvdf"    long_name="Boundary-layer dU"    unit="m/s2" />
720        <field id="dvvdf"    long_name="Boundary-layer dV"    unit="m/s2" />
721        <field id="duoro"    long_name="Orography dU"    unit="m/s2" />
722        <field id="dvoro"    long_name="Orography dV"    unit="m/s2" />
723        <field id="dulif"    long_name="Orography dU"    unit="m/s2" />
724        <field id="dvlif"    long_name="Orography dV"    unit="m/s2" />
725        <field id="du_gwd_rando"    long_name="peu importe"    unit="W/m2" />
726        <field id="dv_gwd_rando"    long_name="peu importe"    unit="W/m2" />
727        <field id="du_gwd_hines" long_name="Hines GWD dU" unit="m/s2" />
728        <field id="dv_gwd_hines" long_name="Hines GWD dV" unit="m/s2" />
729        <field id="du_gwd_front" long_name="Fronts GWD dU" unit="m/s2" />
730        <field id="dv_gwd_front" long_name="Fronts GWD dV" unit="m/s2" />
731        <field id="east_gwstress" long_name="Eastward GW Stress" unit="Pa" />
732        <field id="west_gwstress" long_name="Westward GW Stress" unit="Pa" />
733        <field id="dtoro"    long_name="Orography dT"    unit="K/s" />
734        <field id="dtlif"    long_name="Orography dT"    unit="K/s" />
735        <field id="dthin"    long_name="Hines GWD dT"    unit="K/s" />
736        <field id="tnt"    long_name="Tendency of air temperature"    unit="K s-1" />
737        <field id="tntc"    long_name="Tendency of air temperature due to Moist Convection"    unit="K s-1" />
738        <field id="tntr"    long_name="Air temperature tendency due to Radiative heating"    unit="K s-1" />
739        <field id="tntscpbl"    long_name="Air temperature tendency due to St cloud and precipitation and BL mixing"    unit="K s-1" />
740        <field id="tnhus"    long_name="Tendency of specific humidity"    unit="s-1" />
741        <field id="tnhusc"    long_name="Tendency of specific humidity due to convection"    unit="s-1" />
742        <field id="tnhusscpbl"    long_name="Tendency of Specific humidity due to ST cl, precip and BL mixing"    unit="s-1" />
743        <field id="h2o"    long_name="Mass Fraction of Water"    unit="1" />
744        <field id="mcd"    long_name="Downdraft COnvective Mass Flux"    unit="kg/(m2*s)" />
745        <field id="dmc"    long_name="Deep COnvective Mass Flux"    unit="kg/(m2*s)" />
746        <field id="ref_liq"    long_name="Effective radius of convective cloud liquid water particle"    unit="m" />
747        <field id="ref_ice"    long_name="Effective radius of startiform cloud ice particle"    unit="m" />
748        <field id="stratomask"    long_name="Stratospheric fraction"    unit="-" />
749        <field id="heat_volc"    long_name="SW heating rate from volcano"    unit="K/s" />
750        <field id="cool_volc"    long_name="LW cooling rate from volcano"    unit="K/s" />
751        <field id="dqch4"        long_name="H2O due to CH4 oxidation and photolysis" unit="(kg/kg)/s" />
752        <field id="pvap"    long_name="pvap intermediary variable" unit="-">pres*ovap*461.5 / (287.04*(1.+ (10.9491/18.0153)*ovap)) </field>
753        <field id="oclr"    long_name="Clear sky total water"    unit="kg/kg" />
754        <field id="ocld"    long_name="Cloudy sky total water"   unit="kg/kg" />
755        <field id="oss"     long_name="ISSR total water"    unit="kg/kg" />
756        <field id="ovc"     long_name="In-cloud vapor"    unit="kg/kg" />
757        <field id="rnebclr"    long_name="Clear sky fraction"    unit="-" />
758        <field id="rnebss"     long_name="ISSR fraction"     unit="-" />
759        <field id="rnebseri"   long_name="Cloud fraction"    unit="-" />
760        <field id="gammass"    long_name="Supersaturation ratio"    unit="-" />
761        <field id="N1ss"       long_name="N1ss"    unit="-" />
762        <field id="N2ss"       long_name="N2ss"    unit="-" />
763        <field id="drnebsub"   long_name="Cloud fraction change because of sublimation"    unit="s-1" />
764        <field id="drnebcon"   long_name="Cloud fraction change because of condensation"   unit="s-1" />
765        <field id="drnebtur"   long_name="Cloud fraction change because of turbulence"     unit="s-1" />
766        <field id="drnebavi"   long_name="Cloud fraction change because of aviation"       unit="s-1" />
767        <field id="qsatl"      long_name="Saturation with respect to liquid water"    unit="-" />
768        <field id="qsats"      long_name="Saturation with respect to liquid ice"      unit="-" />
769        <field id="flightm"    long_name="Aviation meters flown"      unit="m/s" />
770        <field id="flighth2o"  long_name="Aviation H2O emitted"       unit="kg H2O/s" />
771        <field id="fcontrP"    long_name="Gridbox fraction with potential persistent contrails"     unit="-" />
772        <field id="fcontrN"    long_name="Gridbox fraction with potential non-persistent contrails"     unit="-" />
773        <field id="qcontr"     long_name="Contrail qcontr"     unit="Pa" />
774        <field id="qcontr2"     long_name="Contrail qcontr2"     unit="kg/kg" />
775        <field id="Tcontr"     long_name="Contrail Tcontr"     unit="K" />
776        <field id="fluxt"     long_name="flux h"     unit="W/m2" />
777        <field id="fluxq"     long_name="flux q"     unit="-" />
778    </field_group>
779
780    <field_group id="fields_3Dkp1" grid_ref="grid_glo_presinter" >
781        <field id="a_th"    long_name="Thermal plume fraction"    unit="-" />
782        <field id="f_th"    long_name="Thermal plume mass flux"    unit="kg/(m2*s)" />
783        <field id="w_th"    long_name="Thermal plume vertical velocity"    unit="m/s" />
784        <field id="rsucs"    long_name="SW CS upward radiation"    unit="W m-2" />
785        <field id="rsdcs"    long_name="SW CS downward radiation"    unit="W m-2" />
786        <field id="rlucs"    long_name="LW CS upward radiation"    unit="W m-2" />
787        <field id="rldcs4co2"    long_name="Downwelling CS LW 4xCO2 atmosphere"    unit="W/m2" />
788        <field id="rlucs4co2"    long_name="Upwelling CS LW 4xCO2 atmosphere"    unit="W/m2" />
789        <field id="rsdcs4co2"    long_name="Downwelling CS SW 4xCO2 atmosphere"    unit="W/m2" />
790        <field id="rsucs4co2"    long_name="Upwelling CS SW 4xCO2 atmosphere"    unit="W/m2" />
791        <field id="rld4co2"    long_name="Downwelling LW 4xCO2 atmosphere"    unit="W/m2" />
792        <field id="rsd4co2"    long_name="Downwelling SW 4xCO2 atmosphere"    unit="W/m2" />
793        <field id="rlu4co2"    long_name="Upwelling LW 4xCO2 atmosphere"    unit="W/m2" />
794        <field id="rsu4co2"    long_name="Upwelling SW 4xCO2 atmosphere"    unit="W/m2" />
795        <field id="rsdcsaf"  long_name="SW clean (no aerosol) CS downward radiation"    unit="W m-2" />
796        <field id="rsucsaf"  long_name="SW clean (no aerosol) CS upward radiation"    unit="W m-2" />
797        <field id="Vprecip"    long_name="precipitation vertical profile"    unit="-" />
798        <field id="kz_max"    long_name="Kz melange max"    unit="m2/s" enabled="FALSE" operation="maximum" />
799        <field id="rldcs"    long_name="LW CS downward radiation"    unit="W m-2" />
800        <field id="rsu"    long_name="SW upward radiation"    unit="W m-2" />
801        <field id="rsd"    long_name="SW downward radiation"    unit="W m-2" />
802        <field id="rlu"    long_name="LW upward radiation"    unit="W m-2" />
803        <field id="rld"    long_name="LW downward radiation"    unit="W m-2" />
804        <field id="kz"    long_name="Kz melange"    unit="m2/s" enabled="FALSE" />
805        <field id="evu"    long_name="Eddy viscosity coefficient for Momentum Variables"    unit="m2 s-1" />
806    </field_group>
807   
808    <field_group id="fields_strataer_trac_3D" grid_ref="grid_glo_presnivs" operation="average"/>
809    <field_group id="fields_strataer_trac_2D" grid_ref="grid_glo" operation="average"/>
810
811    <field_group id="fields_strataer_3D" grid_ref="grid_glo_presnivs" operation="average" >
812        <field id="ext_strat_550"        long_name="Strat. aerosol extinction coefficient at 550 nm"       unit="1/m" />
813        <field id="ext_strat_1020"       long_name="Strat. aerosol extinction coefficient at 1020 nm"      unit="1/m" />
814        <field id="budg_3D_nucl"         long_name="H2SO4 nucleation mass flux"                            unit="kg(S)/m2/layer/s" />
815        <field id="budg_3D_cond_evap"    long_name="H2SO4 net condensation/evaporation mass flux"          unit="kg(S)/m2/layer/s" />
816        <field id="budg_3D_ocs_to_so2"   long_name="OCS mass flux converted to SO2"                        unit="kg(S)/m2/layer/s" />
817        <field id="budg_3D_so2_to_h2so4" long_name="SO2 mass flux converted to H2SO4"                      unit="kg(S)/m2/layer/s" />
818        <field id="budg_3D_backgr_ocs"   long_name="OCS background tendency"                               unit="kg(S)/m2/layer/s" />
819        <field id="budg_3D_backgr_so2"   long_name="SO2 background tendency"                               unit="kg(S)/m2/layer/s" />
820        <field id="R2SO4"                long_name="H2SO4 mass fraction in aerosol"                        unit="%" />
821        <field id="OCS_lifetime"         long_name="OCS lifetime"                                          unit="s" />
822        <field id="SO2_lifetime"         long_name="SO2 lifetime"                                          unit="s" />
823        <field id="vsed_aer"             long_name="Strat. aerosol sedimentation velocity (mass-weighted)" unit="m/s" />
824        <field id="f_r_wet"              long_name="Conversion factor dry to wet aerosol radius"           unit="-" />
825    </field_group>
826
827    <field_group id="fields_strataer_2D" grid_ref="grid_glo" operation="average">
828        <field id="OD550_strat_only"   long_name="Stratospheric Aerosol Optical depth at 550 nm "        unit="1" />
829        <field id="OD1020_strat_only"  long_name="Stratospheric Aerosol Optical depth at 1020 nm "       unit="1" />
830        <field id="surf_PM25_sulf"     long_name="Sulfate PM2.5 concentration at the surface"            unit="ug/m3" />
831        <field id="budg_dep_dry_ocs"   long_name="OCS dry deposition flux"                               unit="kg(S)/m2/s" />
832        <field id="budg_dep_wet_ocs"   long_name="OCS wet deposition flux"                               unit="kg(S)/m2/s" />
833        <field id="budg_dep_dry_so2"   long_name="SO2 dry deposition flux"                               unit="kg(S)/m2/s" />
834        <field id="budg_dep_wet_so2"   long_name="SO2 wet deposition flux"                               unit="kg(S)/m2/s" />
835        <field id="budg_dep_dry_h2so4" long_name="H2SO4 dry deposition flux"                             unit="kg(S)/m2/s" />
836        <field id="budg_dep_wet_h2so4" long_name="H2SO4 wet deposition flux"                             unit="kg(S)/m2/s" />
837        <field id="budg_dep_dry_part"  long_name="Particle S dry deposition flux"                        unit="kg(S)/m2/s" />
838        <field id="budg_dep_wet_part"  long_name="Particle S wet deposition flux"                        unit="kg(S)/m2/s" />
839        <field id="budg_emi_ocs"       long_name="OCS emission flux"                                     unit="kg(S)/m2/s" />
840        <field id="budg_emi_so2"       long_name="SO2 emission flux"                                     unit="kg(S)/m2/s" />
841        <field id="budg_emi_h2so4"     long_name="H2SO4 emission flux"                                   unit="kg(S)/m2/s" />
842        <field id="budg_emi_part"      long_name="Particle S emission flux"                              unit="kg(S)/m2/s" />
843        <field id="budg_ocs_to_so2"    long_name="OCS to SO2 conversion flux"                            unit="kg(S)/m2/s" />
844        <field id="budg_so2_to_h2so4"  long_name="SO2 to H2SO4 conversion flux"                          unit="kg(S)/m2/s" />
845        <field id="budg_h2so4_to_part" long_name="H2SO4 to particle conversion flux"                     unit="kg(S)/m2/s" />
846        <field id="budg_sed_part"      long_name="Ground sedimentation flux of strat. particles"         unit="kg(S)/m2/s" />
847    </field_group>
848   
849    <field_group  id="fields_NMC" grid_ref="grid_glo_plev" >
850<!--  <field id="tnondef" long_name="Undefined value of T" unit="K" detect_missing_value=".true." /> -->
851      <field id="ta" long_name="Air temperature" unit="K" detect_missing_value=".true." />
852      <field id="zg" long_name="Geopotential height" unit="m" detect_missing_value=".true." />
853      <field id="hus" long_name="Specific humidity" unit="1" detect_missing_value=".true." />
854      <field id="hur" long_name="Relative humidity" unit="%" detect_missing_value=".true." />
855      <field id="ua" long_name="Eastward wind" unit="m s-1" detect_missing_value=".true." />
856      <field id="va" long_name="Northward wind" unit="m s-1" detect_missing_value=".true." />
857      <field id="wap" long_name="Lagrangian tendency of air pressure" unit="Pa s-1" detect_missing_value=".true." />
858<!--  <field id="psbg" long_name="Pressure sfce below ground" unit="%" detect_missing_value=".true." /> -->
859      <field id="tro3" long_name="Ozone mole fraction" unit="1e-9" detect_missing_value=".true." />
860      <field id="tro3_daylight" long_name="Daylight ozone mole fraction" unit="1e-9" detect_missing_value=".true." />
861      <field id="uv" long_name="uv" unit="m2/s2" detect_missing_value=".true." />
862      <field id="vxq" long_name="vxq" unit="m/s * (kg/kg)" detect_missing_value=".true." />
863      <field id="vT" long_name="vT" unit="mK/s" detect_missing_value=".true." />
864      <field id="wq" long_name="wq" unit="(Pa/s)*(kg/kg)" detect_missing_value=".true." />
865      <field id="vphi" long_name="vphi" unit="m2/s" detect_missing_value=".true." />
866      <field id="wT" long_name="wT" unit="K*Pa/s" detect_missing_value=".true." />
867      <field id="u2" long_name="u2" unit="m2/s2" detect_missing_value=".true." />
868      <field id="v2" long_name="v2" unit="m2/s2" detect_missing_value=".true." />
869      <field id="T2" long_name="T2" unit="K2" detect_missing_value=".true." />
870    </field_group>
871
872
873
874    <field_group id="fields_phystokenc_3D" domain_ref="dom_glo" axis_ref="klev"   >
875      <field id="t_stok"         long_name="Temperature" unit="K" />
876      <field id="coefh_stok"     long_name="coeff de melange dans la couche limite" unit="-" />
877      <field id="fm_th_stok"     long_name="Mass flux thermals" unit="kg m-2.s-1" />
878      <field id="en_th_stok"     long_name="Thermal plume entrainment" unit="kg m-1.s-1" />
879      <field id="da_stok"        long_name="adiabatic ascen" unit="kg m-2.s-1" />
880      <field id="mp_stok"        long_name="precipitating downdraft mass flux under hydrostatic approximation" unit="kg m-2.s-1" />
881      <field id="wght_stok"      long_name="weights of the layers feeding convection" unit="-" />
882      <field id="upwd_stok"      long_name="saturated updraft mass flux" unit="kg m-2.s-1" />
883      <field id="dnwd_stok"      long_name="saturated downdraft mass flux" unit="kg m-2.s-1" />
884    </field_group>
885   
886    <field_group id="philev_grp" long_name="mass flow environmental mixing" unit="kg m-2 s-1" domain_ref="dom_glo" axis_ref="klev" operation="average"/>
887
888    <field_group id="fields_phystokenc_2D" grid_ref="grid_glo" >
889      <field id="yu1_stok"       long_name="zonal surface wind" unit="m.s-1" />
890      <field id="yv1_stok"       long_name="wind meridian surface" unit="m.s-1" />
891    </field_group>
892
893
894   
895    <field_group id="fields_trac_2D" grid_ref="grid_glo" >
896          <field id="cumRN"    long_name="Cumulated tracer  RNVL1"    unit="-" />
897          <field id="cumPB"    long_name="Cumulated tracer  PBVL1"    unit="-" />
898          <field id="cumAga"   long_name="Cumulated tracer  Aga"    unit="-" />
899          <field id="cumCO2"   long_name="Cumulated tracer  CO2"    unit="-" />
900          <field id="cumdRN_dry"  long_name="Surface dry deposition tracer  RNVL1"  unit="- s-1" />
901          <field id="cumdPB_dry"  long_name="Surface dry deposition tracer  PBVL1"  unit="- s-1" />
902          <field id="cumdAga_dry" long_name="Surface dry deposition tracer  Aga"    unit="- s-1" />
903          <field id="cumdCO2_dry" long_name="Surface dry deposition tracer  CO2"    unit="- s-1" />
904    </field_group>
905
906    <field_group id="fields_trac_3D" grid_ref="grid_glo_presnivs" >
907      <field id="RN"    long_name="Tracer RNVL1"    unit="-" />
908      <field id="dRN_vdf"    long_name="Tendance tracer RNVL1"    unit="-" />
909      <field id="dRN_the"    long_name="Tendance tracer  RNVL1"    unit="-" />
910      <field id="dRN_con"    long_name="Tendance tracer  RNVL1"    unit="-" />
911      <field id="dRN_lessi_impa"    long_name="Tendance tracer  RNVL1"    unit="-" />
912      <field id="dRN_lessi_nucl"    long_name="Tendance tracer  RNVL1"    unit="-" />
913      <field id="dRN_insc"    long_name="Tendance tracer  RNVL1"    unit="-" />
914      <field id="dRN_bcscav"    long_name="Tendance tracer  RNVL1"    unit="-" />
915      <field id="dRN_evapls"    long_name="Tendance tracer  RNVL1"    unit="-" />
916      <field id="dRN_ls"    long_name="Tendance tracer  RNVL1"    unit="-" />
917      <field id="dRN_trsp"    long_name="Tendance tracer  RNVL1"    unit="-" />
918      <field id="dRN_sscav"    long_name="Tendance tracer  RNVL1"    unit="-" />
919      <field id="dRN_sat"    long_name="Tendance tracer  RNVL1"    unit="-" />
920      <field id="dRN_uscav"    long_name="Tendance tracer  RNVL1"    unit="-" />
921      <field id="PB"    long_name="Tracer PBVL1"    unit="-" />
922      <field id="dPB_vdf"    long_name="Tendance tracer PBVL1"    unit="-" />
923      <field id="dPB_the"    long_name="Tendance tracer  PBVL1"    unit="-" />
924      <field id="dPB_con"    long_name="Tendance tracer  PBVL1"    unit="-" />
925      <field id="dPB_lessi_impa"    long_name="Tendance tracer  PBVL1"    unit="-" />
926      <field id="dPB_lessi_nucl"    long_name="Tendance tracer  PBVL1"    unit="-" />
927      <field id="dPB_insc"    long_name="Tendance tracer  PBVL1"    unit="-" />
928      <field id="dPB_bcscav"    long_name="Tendance tracer  PBVL1"    unit="-" />
929      <field id="dPB_evapls"    long_name="Tendance tracer  PBVL1"    unit="-" />
930      <field id="dPB_ls"    long_name="Tendance tracer  PBVL1"    unit="-" />
931      <field id="dPB_trsp"    long_name="Tendance tracer  PBVL1"    unit="-" />
932      <field id="dPB_sscav"    long_name="Tendance tracer  PBVL1"    unit="-" />
933      <field id="dPB_sat"    long_name="Tendance tracer  PBVL1"    unit="-" />
934      <field id="dPB_uscav"    long_name="Tendance tracer  PBVL1"    unit="-" />
935      <field id="Aga"    long_name="Tracer AgaVL1"    unit="-" />
936      <field id="dAga_vdf"    long_name="Tendance tracer Aga"    unit="-" />
937      <field id="dAga_the"    long_name="Tendance tracer  Aga"    unit="-" />
938      <field id="dAga_con"    long_name="Tendance tracer  Aga"    unit="-" />
939      <field id="dAga_lessi_impa"    long_name="Tendance tracer  Aga"    unit="-" />
940      <field id="dAga_lessi_nucl"    long_name="Tendance tracer  Aga"    unit="-" />
941      <field id="dAga_insc"    long_name="Tendance tracer  Aga"    unit="-" />
942      <field id="dAga_bcscav"    long_name="Tendance tracer  Aga"    unit="-" />
943      <field id="dAga_evapls"    long_name="Tendance tracer  Aga"    unit="-" />
944      <field id="dAga_ls"    long_name="Tendance tracer  Aga"    unit="-" />
945      <field id="dAga_trsp"    long_name="Tendance tracer  Aga"    unit="-" />
946      <field id="dAga_sscav"    long_name="Tendance tracer  Aga"    unit="-" />
947      <field id="dAga_sat"    long_name="Tendance tracer  Aga"    unit="-" />
948      <field id="dAga_uscav"    long_name="Tendance tracer  Aga"    unit="-" />
949      <field id="CO2"    long_name="Tracer CO2VL1"    unit="-" />
950      <field id="dCO2_vdf"    long_name="Tendance tracer CO2"    unit="-" />
951      <field id="dCO2_the"    long_name="Tendance tracer  CO2"    unit="-" />
952      <field id="dCO2_con"    long_name="Tendance tracer  CO2"    unit="-" />
953    </field_group>
954
955    <field_group id="fields_solbnd_3D" grid_ref="grid_glo_spectband" >
956      <field id="solbnd"    long_name="Top-of-Atmosphere Solar Insolation for each band"    unit="W m-2"  enabled="false" /> <!-- this field is not sent by LMDZ, vertical axis "spectband" is not properly defined -->
957    </field_group>
958
959<!-- ----------------------------COSP------------------------ -->
960    <field_group src="./field_def_cosp1.xml"/>
961    <!-- <field_group src="./field_def_cospv2.xml"/> -->
962
963
964    <field_group id="fields_AIRS" grid_ref="grid_glo" operation="instant" freq_op="3h">
965      <field id="alt_tropo" long_name="Tropopause pressure" unit="hPa" />
966      <field id="map_prop_hc" long_name="Proportion of high clouds" unit=" "/>
967      <field id="map_prop_hist" long_name="Proportion of high ice semi-transp clouds" unit=" "/>
968      <field id="map_emis_hc" long_name="Emissivity of high clouds" unit=" "/>
969      <field id="map_iwp_hc" long_name="Ice water path of high clouds" unit="g/m2"/>
970      <field id="map_deltaz_hc" long_name="geom thickness of high clouds" unit="m"/>
971      <field id="map_pcld_hc" long_name="cloud pressure of high clouds" unit="hPa"/>
972      <field id="map_tcld_hc" long_name="cloud temperature of high clouds" unit="K"/>
973      <field id="map_emis_hist" long_name="Emissivity of high ice st clouds" unit=" "/>
974      <field id="map_iwp_hist" long_name="Ice water path of high ice st clouds" unit="g/m2"/>
975      <field id="map_deltaz_hist" long_name="geom thickness of high ice st clouds" unit="m"/>
976      <field id="map_rad_hist" long_name="ice crystals radius in high ice st clouds" unit="m"/>
977      <field id="map_emis_Cb" long_name="Emissivity of high Cb clouds" unit=" "/>
978      <field id="map_pcld_Cb" long_name="cloud pressure of high Cb clouds" unit="hPa"/>
979      <field id="map_tcld_Cb" long_name="cloud temperature of high Cb clouds" unit="K"/>
980      <field id="map_emis_Anv" long_name="Emissivity of high Anv clouds" unit=" "/>
981      <field id="map_pcld_Anv" long_name="cloud pressure of high Anv clouds" unit="hPa"/>
982      <field id="map_tcld_Anv" long_name="cloud temperature of high Anv clouds" unit="K"/>
983      <field id="map_emis_ThCi" long_name="Emissivity of high ThCi clouds" unit=" "/>
984      <field id="map_pcld_ThCi" long_name="cloud pressure of high ThCi clouds" unit="hPa"/>
985      <field id="map_tcld_ThCi" long_name="cloud temperature of high ThCi clouds" unit="K"/>
986      <field id="map_ntot" long_name="total AIRS cloud fraction" unit=" "/>
987      <field id="map_hc" long_name="high clouds AIRS cloud fraction" unit=" "/>
988      <field id="map_hist" long_name="high clouds ice st AIRS cloud fraction" unit=" "/>
989      <field id="map_Cb" long_name="high clouds Cb AIRS cloud fraction" unit=" "/>
990      <field id="map_ThCi" long_name="high clouds ThCi AIRS cloud fraction" unit=" "/>
991      <field id="map_Anv" long_name="high clouds Anv AIRS cloud fraction" unit=" "/>
992    </field_group>
993
994   <field_group id="field_scalar" operation="instant" grid_ref="grid_scalar">
995      <field id="R_ecc" long_name="R_ecc" unit="-" />
996      <field id="R_peri" long_name="R_peri" unit="-" />
997      <field id="R_incl" long_name="R_incl" unit="deg" />
998      <field id="solaire" long_name="solaire" unit="W/m2" />
999      <field id="rsun1" long_name="Fraction constante solaire bande 1" unit="W/m2" />
1000      <field id="rsun2" long_name="Fraction constante solaire bande 2" unit="W/m2" />
1001      <field id="rsun3" long_name="Fraction constante solaire bande 3" unit="W/m2" />
1002      <field id="rsun4" long_name="Fraction constante solaire bande 4" unit="W/m2" />
1003      <field id="rsun5" long_name="Fraction constante solaire bande 5" unit="W/m2" />
1004      <field id="rsun6" long_name="Fraction constante solaire bande 6" unit="W/m2" />
1005      <field id="co2_ppm" long_name="co2_ppm" unit="ppm" />
1006      <field id="CH4_ppb" long_name="CH4_ppb" unit="ppb" />
1007      <field id="N2O_ppb" long_name="N2O_ppb" unit="ppb" />
1008      <field id="CFC11_ppt" long_name="CFC11_ppt" unit="ppt" />
1009      <field id="CFC12_ppt" long_name="CFC12_ppt" unit="ppt" />
1010<!-- reducing mass 3D variable to atmosphere total mass scalar -->
1011      <field id="mass_sum_axis"    field_ref="mass" grid_ref="grid_sum_axis" freq_op="1mo" > @mass  </field>
1012      <field id="mass_sum" field_ref="mass_sum_axis" grid_ref="grid_sum" freq_op="1mo" > @mass_sum_axis*aire  </field>
1013   </field_group>
1014
1015</field_definition>
Note: See TracBrowser for help on using the repository browser.