1 | ! |
---|
2 | ! $Id: climoz_mod.F90 3065 2017-11-10 13:25:09Z dcugnet $ |
---|
3 | ! |
---|
4 | ! This module may contains all subroutine and function used |
---|
5 | ! for ozone climatology |
---|
6 | ! code re-design is needed |
---|
7 | |
---|
8 | MODULE climoz_mod |
---|
9 | |
---|
10 | |
---|
11 | |
---|
12 | |
---|
13 | |
---|
14 | CONTAINS |
---|
15 | |
---|
16 | |
---|
17 | SUBROUTINE create_climoz(read_climoz) |
---|
18 | USE mod_grid_phy_lmdz, ONLY : grid_type, unstructured |
---|
19 | USE regr_lat_time_climoz_m |
---|
20 | USE mod_phys_lmdz_para |
---|
21 | #ifdef CPP_XIOS |
---|
22 | USE XIOS |
---|
23 | #endif |
---|
24 | IMPLICIT NONE |
---|
25 | INTEGER, INTENT(IN) :: read_climoz |
---|
26 | |
---|
27 | !--- OZONE CLIMATOLOGY |
---|
28 | IF (grid_type==unstructured) THEN |
---|
29 | #ifdef CPP_XIOS |
---|
30 | IF(read_climoz>=1) THEN |
---|
31 | IF (is_master) CALL regr_lat_time_climoz(read_climoz,.FALSE.) |
---|
32 | IF (is_omp_master) THEN |
---|
33 | CALL xios_set_field_attr( "tro3_reg", enabled=.TRUE.) |
---|
34 | CALL xios_set_field_attr( "tro3_read", enabled=.TRUE.) |
---|
35 | IF (read_climoz==2) THEN |
---|
36 | CALL xios_set_field_attr( "tro3_daylight_reg", enabled=.TRUE.) |
---|
37 | CALL xios_set_field_attr( "tro3_daylight_read", enabled=.TRUE.) |
---|
38 | ENDIF |
---|
39 | ENDIF |
---|
40 | ENDIF |
---|
41 | #endif |
---|
42 | ENDIF |
---|
43 | |
---|
44 | END SUBROUTINE create_climoz |
---|
45 | |
---|
46 | |
---|
47 | |
---|
48 | SUBROUTINE get_ozone_var(name,press_in_edg,paprs,v3) |
---|
49 | USE dimphy |
---|
50 | USE mod_phys_lmdz_para |
---|
51 | #ifdef CPP_XIOS |
---|
52 | USE xios |
---|
53 | #endif |
---|
54 | USE regr1_step_av_m, only: regr1_step_av |
---|
55 | IMPLICIT NONE |
---|
56 | CHARACTER(LEN=*), INTENT(in):: name(:) ! of the NetCDF variables |
---|
57 | REAL, INTENT(IN):: press_in_edg(:) ! edges of pressure intervals for input data, in Pa, in strictly ascending order |
---|
58 | REAL, INTENT(IN):: paprs(:, :) ! (klon, klev + 1) |
---|
59 | REAL, INTENT(OUT):: v3(:, :, :) ! (klon, klev, size(name)) |
---|
60 | |
---|
61 | REAL :: v1_mpi(klon_mpi, size(press_in_edg) - 1, size(v3,3)) |
---|
62 | REAL :: v1(klon, size(press_in_edg) - 1, size(v3,3)) |
---|
63 | INTEGER :: m,i |
---|
64 | |
---|
65 | #ifdef CPP_XIOS |
---|
66 | DO m=1,size(name) |
---|
67 | IF (is_omp_master) CALL xios_recv_field(name(m),v1_mpi(:,:,m)) |
---|
68 | CALL scatter_omp(v1_mpi,v1) |
---|
69 | ! Regrid in pressure at each horizontal position: |
---|
70 | DO i = 1, klon |
---|
71 | v3(i, klev:1:-1, m) = regr1_step_av(v1(i,:,m), press_in_edg, & |
---|
72 | paprs(i, klev+1:1:-1)) |
---|
73 | ! (invert order of indices because "paprs" is in descending order) |
---|
74 | END DO |
---|
75 | ENDDO |
---|
76 | #endif |
---|
77 | END SUBROUTINE get_ozone_var |
---|
78 | |
---|
79 | |
---|
80 | END MODULE climoz_mod |
---|