[5099] | 1 | |
---|
[1279] | 2 | ! $Id: YOECUMF.h 5128 2024-07-25 15:47:25Z abarral $ |
---|
[5099] | 3 | |
---|
[1279] | 4 | ! ATTENTION!!!!: ce fichier include est compatible format fixe/format libre |
---|
| 5 | ! veillez n'utiliser que des ! pour les commentaires |
---|
| 6 | ! et bien positionner les & des lignes de continuation |
---|
| 7 | ! (les placer en colonne 6 et en colonne 73) |
---|
[5099] | 8 | |
---|
[1279] | 9 | ! ---------------------------------------------------------------- |
---|
| 10 | !* *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME |
---|
| 11 | ! ---------------------------------------------------------------- |
---|
[5099] | 12 | |
---|
[1279] | 13 | COMMON /YOECUMF/ & |
---|
[5128] | 14 | ENTRPEN,ENTRSCV,ENTRMID,ENTRDD,CMFCTOP, & |
---|
| 15 | CMFCMAX,CMFCMIN,CMFDEPS,RHCDD,CPRCON, & |
---|
| 16 | LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV |
---|
[1279] | 17 | |
---|
[5081] | 18 | |
---|
[524] | 19 | LOGICAL LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV |
---|
| 20 | REAL ENTRPEN, ENTRSCV, ENTRMID, ENTRDD |
---|
| 21 | REAL CMFCTOP, CMFCMAX, CMFCMIN, CMFDEPS, RHCDD, CPRCON |
---|
[1279] | 22 | !$OMP THREADPRIVATE(/YOECUMF/) |
---|
[5099] | 23 | |
---|
[1279] | 24 | !*if (DOC,declared) <> 'UNKNOWN' |
---|
| 25 | !* *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME |
---|
[5099] | 26 | |
---|
[1279] | 27 | ! M.TIEDTKE E. C. M. W. F. 18/1/89 |
---|
[5099] | 28 | |
---|
[1279] | 29 | ! NAME TYPE PURPOSE |
---|
| 30 | ! ---- ---- ------- |
---|
[5099] | 31 | |
---|
[1279] | 32 | ! LMFPEN LOGICAL TRUE IF PENETRATIVE CONVECTION IS SWITCHED ON |
---|
| 33 | ! LMFSCV LOGICAL TRUE IF SHALLOW CONVECTION IS SWITCHED ON |
---|
| 34 | ! LMFMID LOGICAL TRUE IF MIDLEVEL CONVECTION IS SWITCHED ON |
---|
| 35 | ! LMFDD LOGICAL TRUE IF CUMULUS DOWNDRAFT IS SWITCHED ON |
---|
| 36 | ! LMFDUDV LOGICAL TRUE IF CUMULUS FRICTION IS SWITCHED ON |
---|
| 37 | ! ENTRPEN REAL ENTRAINMENT RATE FOR PENETRATIVE CONVECTION |
---|
| 38 | ! ENTRSCV REAL ENTRAINMENT RATE FOR SHALLOW CONVECTION |
---|
| 39 | ! ENTRMID REAL ENTRAINMENT RATE FOR MIDLEVEL CONVECTION |
---|
| 40 | ! ENTRDD REAL ENTRAINMENT RATE FOR CUMULUS DOWNDRAFTS |
---|
| 41 | ! CMFCTOP REAL RELAT. CLOUD MASSFLUX AT LEVEL ABOVE NONBUOYANC |
---|
| 42 | ! CMFCMAX REAL MAXIMUM MASSFLUX VALUE ALLOWED FOR |
---|
| 43 | ! CMFCMIN REAL MINIMUM MASSFLUX VALUE (FOR SAFETY) |
---|
| 44 | ! CMFDEPS REAL FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS |
---|
| 45 | ! RHCDD REAL RELATIVE SATURATION IN DOWNDRAFTS |
---|
| 46 | ! CPRCON REAL COEFFICIENTS FOR DETERMINING CONVERSION |
---|
| 47 | ! FROM CLOUD WATER TO RAIN |
---|
| 48 | !*ifend |
---|
| 49 | ! ---------------------------------------------------------------- |
---|