source: LMDZ5/branches/testing/libf/phylmd/YOECUMF.h @ 5423

Last change on this file since 5423 was 1910, checked in by Laurent Fairhead, 11 years ago

Merged trunk changes r1860:1909 into testing branch

  • Property copyright set to
    Name of program: LMDZ
    Creation date: 1984
    Version: LMDZ5
    License: CeCILL version 2
    Holder: Laboratoire de m\'et\'eorologie dynamique, CNRS, UMR 8539
    See the license file in the root directory
  • Property svn:eol-style set to native
  • Property svn:keywords set to Author Date Id Revision
File size: 2.3 KB
RevLine 
[524]1!
[1279]2! $Id: YOECUMF.h 1910 2013-11-29 08:40:25Z evignon $
[524]3!
[1279]4!  ATTENTION!!!!: ce fichier include est compatible format fixe/format libre
5!                 veillez n'utiliser que des ! pour les commentaires
6!                 et bien positionner les & des lignes de continuation
7!                 (les placer en colonne 6 et en colonne 73)
8!
9!     ----------------------------------------------------------------
10!*    *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME
11!     ----------------------------------------------------------------
12!
13      COMMON /YOECUMF/                                                  &
14     &                 LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV,              &
15     &                 ENTRPEN,ENTRSCV,ENTRMID,ENTRDD,CMFCTOP,          &
16     &                 CMFCMAX,CMFCMIN,CMFDEPS,RHCDD,CPRCON
17
[524]18      LOGICAL          LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV
19      REAL ENTRPEN, ENTRSCV, ENTRMID, ENTRDD
20      REAL CMFCTOP, CMFCMAX, CMFCMIN, CMFDEPS, RHCDD, CPRCON
[1279]21!$OMP THREADPRIVATE(/YOECUMF/)
22!
23!*if (DOC,declared) <> 'UNKNOWN'
24!*    *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME
25!
26!     M.TIEDTKE       E. C. M. W. F.      18/1/89
27!
28!     NAME      TYPE      PURPOSE
29!     ----      ----      -------
30!
31!     LMFPEN    LOGICAL  TRUE IF PENETRATIVE CONVECTION IS SWITCHED ON
32!     LMFSCV    LOGICAL  TRUE IF SHALLOW     CONVECTION IS SWITCHED ON
33!     LMFMID    LOGICAL  TRUE IF MIDLEVEL    CONVECTION IS SWITCHED ON
34!     LMFDD     LOGICAL  TRUE IF CUMULUS DOWNDRAFT      IS SWITCHED ON
35!     LMFDUDV   LOGICAL  TRUE IF CUMULUS FRICTION       IS SWITCHED ON
36!     ENTRPEN   REAL     ENTRAINMENT RATE FOR PENETRATIVE CONVECTION
37!     ENTRSCV   REAL     ENTRAINMENT RATE FOR SHALLOW CONVECTION
38!     ENTRMID   REAL     ENTRAINMENT RATE FOR MIDLEVEL CONVECTION
39!     ENTRDD    REAL     ENTRAINMENT RATE FOR CUMULUS DOWNDRAFTS
40!     CMFCTOP   REAL     RELAT. CLOUD MASSFLUX AT LEVEL ABOVE NONBUOYANC
41!     CMFCMAX   REAL     MAXIMUM MASSFLUX VALUE ALLOWED FOR
42!     CMFCMIN   REAL     MINIMUM MASSFLUX VALUE (FOR SAFETY)
43!     CMFDEPS   REAL     FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS
44!     RHCDD     REAL     RELATIVE SATURATION IN DOWNDRAFTS
45!     CPRCON    REAL     COEFFICIENTS FOR DETERMINING CONVERSION
46!                        FROM CLOUD WATER TO RAIN
47!*ifend
48!     ----------------------------------------------------------------
Note: See TracBrowser for help on using the repository browser.