source: LMDZ5/branches/LMDZ5-DOFOCO/libf/phylmd/thermcell_height.F90 @ 5055

Last change on this file since 5055 was 1403, checked in by Laurent Fairhead, 14 years ago

Merged LMDZ4V5.0-dev branch changes r1292:r1399 to trunk.

Validation:
Validation consisted in compiling the HEAD revision of the trunk,
LMDZ4V5.0-dev branch and the merged sources and running different
configurations on local and SX8 machines comparing results.

Local machine: bench configuration, 32x24x11, gfortran

  • IPSLCM5A configuration (comparison between trunk and merged sources):
    • numerical convergence on dynamical fields over 3 days
    • start files are equivalent (except for RN and PB fields)
    • daily history files equivalent
  • MH07 configuration, new physics package (comparison between LMDZ4V5.0-dev branch and merged sources):
    • numerical convergence on dynamical fields over 3 days
    • start files are equivalent (except for RN and PB fields)
    • daily history files equivalent

SX8 machine (brodie), 96x95x39 on 4 processors:

  • IPSLCM5A configuration:
    • start files are equivalent (except for RN and PB fields)
    • monthly history files equivalent
  • MH07 configuration:
    • start files are equivalent (except for RN and PB fields)
    • monthly history files equivalent

Changes to the makegcm and create_make_gcm scripts to take into account
main programs in F90 files


Fusion de la branche LMDZ4V5.0-dev (r1292:r1399) au tronc principal

Validation:
La validation a consisté à compiler la HEAD de le trunk et de la banche
LMDZ4V5.0-dev et les sources fusionnées et de faire tourner le modéle selon
différentes configurations en local et sur SX8 et de comparer les résultats

En local: 32x24x11, config bench/gfortran

  • pour une config IPSLCM5A (comparaison tronc/fusion):
    • convergence numérique sur les champs dynamiques après 3 jours
    • restart et restartphy égaux (à part sur RN et Pb)
    • fichiers histoire égaux
  • pour une config nlle physique (MH07) (comparaison LMDZ4v5.0-dev/fusion):
    • convergence numérique sur les champs dynamiques après 3 jours
    • restart et restartphy égaux
    • fichiers histoire équivalents

Sur brodie, 96x95x39 sur 4 proc:

  • pour une config IPSLCM5A:
    • restart et restartphy égaux (à part sur RN et PB)
    • pas de différence dans les fichiers histmth.nc
  • pour une config MH07
    • restart et restartphy égaux (à part sur RN et PB)
    • pas de différence dans les fichiers histmth.nc

Changement sur makegcm et create_make-gcm pour pouvoir prendre en compte des
programmes principaux en *F90

  • Property svn:eol-style set to native
  • Property svn:keywords set to Author Date Id Revision
File size: 4.6 KB
Line 
1      SUBROUTINE thermcell_height(ngrid,nlay,lalim,lmin,linter,lmix,  &
2     &           zw2,zlev,lmax,zmax,zmax0,zmix,wmax,lev_out)                           
3
4!-----------------------------------------------------------------------------
5!thermcell_height: calcul des caracteristiques du thermique: zmax,wmax,zmix
6!-----------------------------------------------------------------------------
7      IMPLICIT NONE
8#include "iniprint.h"
9#include "thermcell.h"
10
11      INTEGER ig,l
12      INTEGER ngrid,nlay
13      INTEGER lalim(ngrid),lmin(ngrid)
14      INTEGER lmix(ngrid)
15      REAL linter(ngrid)
16      integer lev_out                           ! niveau pour les print
17
18      REAL zw2(ngrid,nlay+1)
19      REAL zlev(ngrid,nlay+1)
20
21      REAL wmax(ngrid)
22      INTEGER lmax(ngrid)
23      REAL zmax(ngrid)
24      REAL zmax0(ngrid)
25      REAL zmix(ngrid)
26      REAL num(ngrid)
27      REAL denom(ngrid)
28
29      REAL zlevinter(ngrid)
30
31!calcul de la hauteur max du thermique
32      do ig=1,ngrid
33         lmax(ig)=lalim(ig)
34      enddo
35      do ig=1,ngrid
36         do l=nlay,lalim(ig)+1,-1
37            if (zw2(ig,l).le.1.e-10) then
38               lmax(ig)=l-1
39            endif
40         enddo
41      enddo
42
43! On traite le cas particulier qu'il faudrait éviter ou le thermique
44! atteind le haut du modele ...
45      do ig=1,ngrid
46      if ( zw2(ig,nlay) > 1.e-10 ) then
47          print*,'WARNING !!!!! W2 thermiques non nul derniere couche '
48          lmax(ig)=nlay
49      endif
50      enddo
51
52! pas de thermique si couche 1 stable
53      do ig=1,ngrid
54         if (lmin(ig).gt.1) then
55             lmax(ig)=1
56             lmin(ig)=1
57             lalim(ig)=1
58         endif
59      enddo
60!   
61! Determination de zw2 max
62      do ig=1,ngrid
63         wmax(ig)=0.
64      enddo
65
66      do l=1,nlay
67         do ig=1,ngrid
68            if (l.le.lmax(ig)) then
69                if (zw2(ig,l).lt.0.)then
70                  print*,'pb2 zw2<0'
71                endif
72                zw2(ig,l)=sqrt(zw2(ig,l))
73                wmax(ig)=max(wmax(ig),zw2(ig,l))
74            else
75                 zw2(ig,l)=0.
76            endif
77          enddo
78      enddo
79
80!   Longueur caracteristique correspondant a la hauteur des thermiques.
81      do  ig=1,ngrid
82         zmax(ig)=0.
83         zlevinter(ig)=zlev(ig,1)
84      enddo
85
86      if (iflag_thermals_ed.ge.1) then
87
88         num(:)=0.
89         denom(:)=0.
90         do ig=1,ngrid
91          do l=1,nlay
92             num(ig)=num(ig)+zw2(ig,l)*zlev(ig,l)*(zlev(ig,l+1)-zlev(ig,l))
93             denom(ig)=denom(ig)+zw2(ig,l)*(zlev(ig,l+1)-zlev(ig,l))
94          enddo
95       enddo
96       do ig=1,ngrid
97       if (denom(ig).gt.1.e-10) then
98          zmax(ig)=2.*num(ig)/denom(ig)
99          zmax0(ig)=zmax(ig)
100       endif
101       enddo
102
103       else
104
105      do  ig=1,ngrid
106! calcul de zlevinter
107          zlevinter(ig)=(zlev(ig,lmax(ig)+1)-zlev(ig,lmax(ig)))*  &
108     &    linter(ig)+zlev(ig,lmax(ig))-lmax(ig)*(zlev(ig,lmax(ig)+1)  &
109     &    -zlev(ig,lmax(ig)))
110!pour le cas ou on prend tjs lmin=1
111!       zmax(ig)=max(zmax(ig),zlevinter(ig)-zlev(ig,lmin(ig)))
112       zmax(ig)=max(zmax(ig),zlevinter(ig)-zlev(ig,1))
113       zmax0(ig)=zmax(ig)
114      enddo
115
116
117      endif
118!endif iflag_thermals_ed
119!
120! def de  zmix continu (profil parabolique des vitesses)
121      do ig=1,ngrid
122           if (lmix(ig).gt.1) then
123! test
124              if (((zw2(ig,lmix(ig)-1)-zw2(ig,lmix(ig)))  &
125     &        *((zlev(ig,lmix(ig)))-(zlev(ig,lmix(ig)+1)))  &
126     &        -(zw2(ig,lmix(ig))-zw2(ig,lmix(ig)+1))  &
127     &        *((zlev(ig,lmix(ig)-1))-(zlev(ig,lmix(ig))))).gt.1e-10)  &
128     &        then
129!             
130            zmix(ig)=((zw2(ig,lmix(ig)-1)-zw2(ig,lmix(ig)))  &
131     &        *((zlev(ig,lmix(ig)))**2-(zlev(ig,lmix(ig)+1))**2)  &
132     &        -(zw2(ig,lmix(ig))-zw2(ig,lmix(ig)+1))  &
133     &        *((zlev(ig,lmix(ig)-1))**2-(zlev(ig,lmix(ig)))**2))  &
134     &        /(2.*((zw2(ig,lmix(ig)-1)-zw2(ig,lmix(ig)))  &
135     &        *((zlev(ig,lmix(ig)))-(zlev(ig,lmix(ig)+1)))  &
136     &        -(zw2(ig,lmix(ig))-zw2(ig,lmix(ig)+1))  &
137     &        *((zlev(ig,lmix(ig)-1))-(zlev(ig,lmix(ig))))))
138              else
139              zmix(ig)=zlev(ig,lmix(ig))
140              print*,'pb zmix'
141              endif
142          else
143              zmix(ig)=0.
144          endif
145!test
146         if ((zmax(ig)-zmix(ig)).le.0.) then
147            zmix(ig)=0.9*zmax(ig)
148!            print*,'pb zmix>zmax'
149         endif
150      enddo
151!
152! calcul du nouveau lmix correspondant
153      do ig=1,ngrid
154         do l=1,nlay
155            if (zmix(ig).ge.zlev(ig,l).and.  &
156     &          zmix(ig).lt.zlev(ig,l+1)) then
157              lmix(ig)=l
158             endif
159          enddo
160      enddo
161!
162      return
163      end
Note: See TracBrowser for help on using the repository browser.