source: LMDZ4/trunk/libf/dyn3dpar/caladvtrac_p.F @ 5394

Last change on this file since 5394 was 1403, checked in by Laurent Fairhead, 14 years ago

Merged LMDZ4V5.0-dev branch changes r1292:r1399 to trunk.

Validation:
Validation consisted in compiling the HEAD revision of the trunk,
LMDZ4V5.0-dev branch and the merged sources and running different
configurations on local and SX8 machines comparing results.

Local machine: bench configuration, 32x24x11, gfortran

  • IPSLCM5A configuration (comparison between trunk and merged sources):
    • numerical convergence on dynamical fields over 3 days
    • start files are equivalent (except for RN and PB fields)
    • daily history files equivalent
  • MH07 configuration, new physics package (comparison between LMDZ4V5.0-dev branch and merged sources):
    • numerical convergence on dynamical fields over 3 days
    • start files are equivalent (except for RN and PB fields)
    • daily history files equivalent

SX8 machine (brodie), 96x95x39 on 4 processors:

  • IPSLCM5A configuration:
    • start files are equivalent (except for RN and PB fields)
    • monthly history files equivalent
  • MH07 configuration:
    • start files are equivalent (except for RN and PB fields)
    • monthly history files equivalent

Changes to the makegcm and create_make_gcm scripts to take into account
main programs in F90 files


Fusion de la branche LMDZ4V5.0-dev (r1292:r1399) au tronc principal

Validation:
La validation a consisté à compiler la HEAD de le trunk et de la banche
LMDZ4V5.0-dev et les sources fusionnées et de faire tourner le modéle selon
différentes configurations en local et sur SX8 et de comparer les résultats

En local: 32x24x11, config bench/gfortran

  • pour une config IPSLCM5A (comparaison tronc/fusion):
    • convergence numérique sur les champs dynamiques après 3 jours
    • restart et restartphy égaux (à part sur RN et Pb)
    • fichiers histoire égaux
  • pour une config nlle physique (MH07) (comparaison LMDZ4v5.0-dev/fusion):
    • convergence numérique sur les champs dynamiques après 3 jours
    • restart et restartphy égaux
    • fichiers histoire équivalents

Sur brodie, 96x95x39 sur 4 proc:

  • pour une config IPSLCM5A:
    • restart et restartphy égaux (à part sur RN et PB)
    • pas de différence dans les fichiers histmth.nc
  • pour une config MH07
    • restart et restartphy égaux (à part sur RN et PB)
    • pas de différence dans les fichiers histmth.nc

Changement sur makegcm et create_make-gcm pour pouvoir prendre en compte des
programmes principaux en *F90

  • Property svn:eol-style set to native
  • Property svn:keywords set to Author Date Id Revision
File size: 3.3 KB
Line 
1!
2! $Id: caladvtrac_p.F 1403 2010-07-01 09:02:53Z evignon $
3!
4c
5c
6            SUBROUTINE caladvtrac_p(q,pbaru,pbarv ,
7     *                   p ,masse, dq ,  teta,
8     *                   flxw, pk, iapptrac)
9      USE parallel
10      USE infotrac
11      USE control_mod
12c
13      IMPLICIT NONE
14c
15c     Auteurs:   F.Hourdin , P.Le Van, F.Forget, F.Codron 
16c
17c     F.Codron (10/99) : ajout humidite specifique pour eau vapeur
18c=======================================================================
19c
20c       Shema de  Van Leer
21c
22c=======================================================================
23
24
25#include "dimensions.h"
26#include "paramet.h"
27#include "comconst.h"
28
29c   Arguments:
30c   ----------
31      REAL pbaru( ip1jmp1,llm ),pbarv( ip1jm,llm),masse(ip1jmp1,llm)
32      REAL p( ip1jmp1,llmp1),q( ip1jmp1,llm,nqtot),dq( ip1jmp1,llm,2 )
33      REAL teta( ip1jmp1,llm),pk( ip1jmp1,llm)
34      REAL               :: flxw(ip1jmp1,llm)
35
36      integer ijb,ije,jjb,jje
37
38c  ..................................................................
39c
40c  .. dq n'est utilise et dimensionne que pour l'eau  vapeur et liqu.
41c
42c  ..................................................................
43c
44c   Local:
45c   ------
46
47      INTEGER ij,l, iq, iapptrac
48      REAL finmasse(ip1jmp1,llm), dtvrtrac
49     
50cc
51c
52C initialisation
53cym      ijb=ij_begin
54cym      ije=ij_end
55
56     
57cym      dq(ijb:ije,1:llm,1:2)=q(ijb:ije,1:llm,1:2)
58
59c  test des valeurs minmax
60cc        CALL minmaxq(q(1,1,1),1.e33,-1.e33,'Eau vapeur (a) ')
61cc        CALL minmaxq(q(1,1,2),1.e33,-1.e33,'Eau liquide(a) ')
62
63c   advection
64c      print *,'appel a advtrac'
65
66      CALL advtrac_p( pbaru,pbarv,
67     *             p,  masse,q,iapptrac, teta,
68     .             flxw, pk)
69
70         goto 9999
71         IF( iapptrac.EQ.iapp_tracvl ) THEN
72c
73cc          CALL minmaxq(q(1,1,1),1.e33,-1.e33,'Eau vapeur     ')
74cc          CALL minmaxq(q(1,1,2),1.e33,-1.e33,'Eau liquide    ')
75
76cc     ....  Calcul  de deltap  qu'on stocke dans finmasse   ...
77c
78          DO l = 1, llm
79           DO ij = ijb, ije
80             finmasse(ij,l) =  p(ij,l) - p(ij,l+1)
81           ENDDO
82          ENDDO
83
84          if (planet_type.eq."earth") then
85! Earth-specific treatment of first 2 tracers (water)
86            CALL qminimum_p( q, 2, finmasse )
87          endif
88
89
90cym   --> le reste ne set a rien
91          goto 9999
92         
93c          CALL SCOPY   ( ip1jmp1*llm, masse, 1, finmasse,       1 )
94          finmasse(ijb:ije,:)=masse(ijb:ije,:)         
95         
96          jjb=jj_begin
97          jje=jj_end
98          CALL filtreg_p ( finmasse ,jjb,jje,  jjp1,  llm,
99     *                     -2, 2, .TRUE., 1 )
100c
101c   *****  Calcul de dq pour l'eau , pour le passer a la physique ******
102c   ********************************************************************
103c
104          dtvrtrac = iapp_tracvl * dtvr
105c
106           DO iq = 1 , 2
107            DO l = 1 , llm
108             DO ij = ijb,ije
109             dq(ij,l,iq) = ( q(ij,l,iq) - dq(ij,l,iq) ) * finmasse(ij,l)
110     *                               /  dtvrtrac
111             ENDDO
112            ENDDO
113           ENDDO
114c
115         ELSE
116cym   --> le reste ne set a rien
117          goto 9999
118         
119           DO iq = 1 , 2
120           DO l  = 1, llm
121             DO ij = ijb,ije
122              dq(ij,l,iq)  = 0.
123             ENDDO
124           ENDDO
125           ENDDO
126
127         ENDIF
128c
129
130
131c  ... On appelle  qminimum uniquement  pour l'eau vapeur et liquide  ..
132
133 
134 9999 RETURN
135      END
136
137
Note: See TracBrowser for help on using the repository browser.