File size: 1.9 KB
RevLine 
[524]1!
2! $Header$
3!
4C     ----------------------------------------------------------------
5C*    *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME
6C     ----------------------------------------------------------------
7C
8      COMMON /YOECUMF/
9     L                 LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV,
10     R                 ENTRPEN,ENTRSCV,ENTRMID,ENTRDD,CMFCTOP,
11     R                 CMFCMAX,CMFCMIN,CMFDEPS,RHCDD,CPRCON
12C
13      LOGICAL          LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV
14      REAL ENTRPEN, ENTRSCV, ENTRMID, ENTRDD
15      REAL CMFCTOP, CMFCMAX, CMFCMIN, CMFDEPS, RHCDD, CPRCON
[776]16c$OMP THREADPRIVATE(/YOECUMF/)
[524]17C
18*if (DOC,declared) <> 'UNKNOWN'
19C*    *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME
20C
21C     M.TIEDTKE       E. C. M. W. F.      18/1/89
22C
23C     NAME      TYPE      PURPOSE
24C     ----      ----      -------
25C
26C     LMFPEN    LOGICAL  TRUE IF PENETRATIVE CONVECTION IS SWITCHED ON
27C     LMFSCV    LOGICAL  TRUE IF SHALLOW     CONVECTION IS SWITCHED ON
28C     LMFMID    LOGICAL  TRUE IF MIDLEVEL    CONVECTION IS SWITCHED ON
29C     LMFDD     LOGICAL  TRUE IF CUMULUS DOWNDRAFT      IS SWITCHED ON
30C     LMFDUDV   LOGICAL  TRUE IF CUMULUS FRICTION       IS SWITCHED ON
31C     ENTRPEN   REAL     ENTRAINMENT RATE FOR PENETRATIVE CONVECTION
32C     ENTRSCV   REAL     ENTRAINMENT RATE FOR SHALLOW CONVECTION
33C     ENTRMID   REAL     ENTRAINMENT RATE FOR MIDLEVEL CONVECTION
34C     ENTRDD    REAL     ENTRAINMENT RATE FOR CUMULUS DOWNDRAFTS
35C     CMFCTOP   REAL     RELAT. CLOUD MASSFLUX AT LEVEL ABOVE NONBUOYANC
36C     CMFCMAX   REAL     MAXIMUM MASSFLUX VALUE ALLOWED FOR
37C     CMFCMIN   REAL     MINIMUM MASSFLUX VALUE (FOR SAFETY)
38C     CMFDEPS   REAL     FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS
39C     RHCDD     REAL     RELATIVE SATURATION IN DOWNDRAFTS
40C     CPRCON    REAL     COEFFICIENTS FOR DETERMINING CONVERSION
41C                        FROM CLOUD WATER TO RAIN
42*ifend